{"title":"Accessories","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eEverything you need to enhance or retrofit your existing valve automation setup. From solenoid valves to switchboxes, positioners to mounting kits, each component is designed to deliver greater control, feedback, and efficiency to your process — without the need to replace the entire actuator.\u003c\/p\u003e","products":[{"product_id":"viz-001-mechanical-limit-switchbox","title":"VIZ-001 Mechanical Limit Switchbox – SPDT, 250V 10A, IP68, 2 x M20 Entries (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003eSupplied as a pack of 5.\u003c\/strong\u003e The price shown is for the full pack of five units.\u003c\/p\u003e\u003cp data-start=\"303\" data-end=\"607\"\u003eThe VIZ-001 Mechanical Limit Switchbox is a rugged and reliable position feedback device for valve automation. Featuring a Single Pole Double Throw (SPDT) microswitch rated at 250V AC, 10A, it provides accurate open\/close position signalling for electrically or pneumatically actuated valves.\u003c\/p\u003e\n\u003cp data-start=\"609\" data-end=\"886\"\u003eDesigned with an IP68-rated enclosure, this switchbox offers superior protection against water, dust, and harsh industrial environments. It includes 2 x M20 cable entries for flexible wiring and integration, making it suitable for a wide range of on-site installations.\u003c\/p\u003e\n\u003cp data-start=\"888\" data-end=\"1064\"\u003eWith clear mechanical indication and a compact, durable housing, the VIZ-001 is ideal for process control systems requiring dependable valve monitoring in demanding conditions.\u003c\/p\u003e\n\u003cp data-start=\"1066\" data-end=\"1405\"\u003e\u003cstrong data-start=\"1066\" data-end=\"1083\"\u003eKey Features:\u003c\/strong\u003e\u003cbr data-start=\"1083\" data-end=\"1086\"\u003e- SPDT switch rated for 250V, 10A – suitable for high-current applications\u003cbr data-start=\"1161\" data-end=\"1164\"\u003e\u003cmeta charset=\"utf-8\"\u003e- IP68 ingress protection for harsh and wet environments\u003cbr data-start=\"1221\" data-end=\"1224\"\u003e\u003cmeta charset=\"utf-8\"\u003e- 2 x M20 cable entries for flexible electrical connectivity\u003cbr data-start=\"1285\" data-end=\"1288\"\u003e\u003cmeta charset=\"utf-8\"\u003e- Mechanical visual indicator for clear open\/close status\u003cbr data-start=\"1346\" data-end=\"1349\"\u003e\u003cmeta charset=\"utf-8\"\u003e- Ideal for use on actuated ball and butterfly valves\u003c\/p\u003e","brand":"Hygienic Valve","offers":[{"title":"Default Title","offer_id":54938488570181,"sku":"","price":394.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/Viz1Switchbox.png?v=1750078824"},{"product_id":"trewfit-controls-mechanical-limit-switchbox-spdt-250v-10a-ip68-2-x-m20-entries-copy","title":"Trewfit Controls Mechanical Limit Switchbox – SPDT, 250V 10A, IP68, 2 x M20 Entries (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003eSupplied as a pack of 5.\u003c\/strong\u003e The price shown is for the full pack of five units.\u003c\/p\u003e\u003cp data-start=\"277\" data-end=\"625\"\u003eThe Trewfit Controls Mechanical Limit Switchbox provides robust and accurate valve position feedback for industrial automation systems. Fitted with a Single Pole Double Throw (SPDT) microswitch rated for 250V AC, 10A, it ensures reliable signalling for open and closed valve positions in both pneumatic and electric actuator assemblies.\u003c\/p\u003e\n\u003cp data-start=\"627\" data-end=\"912\"\u003eEngineered with a weatherproof IP68 enclosure, the unit is built to withstand dust, moisture, and challenging site conditions. Dual M20 cable entries offer convenient and flexible wiring options, while the mechanical visual indicator allows for quick status checks at a glance.\u003c\/p\u003e\n\u003cp data-start=\"914\" data-end=\"1124\"\u003eIdeal for a range of process industries including water treatment, food and beverage, and chemical processing, this limit switchbox from Trewfit Controls combines durability with dependable performance.\u003c\/p\u003e\n\u003cp data-start=\"1126\" data-end=\"1462\"\u003e\u003cstrong data-start=\"1126\" data-end=\"1143\"\u003eKey Features:\u003c\/strong\u003e\u003cbr data-start=\"1143\" data-end=\"1146\"\u003e- SPDT switch rated 250V 10A for versatile electrical applications\u003cbr data-start=\"1213\" data-end=\"1216\"\u003e\u003cmeta charset=\"utf-8\"\u003e- IP68-rated housing for superior protection in harsh conditions\u003cbr data-start=\"1281\" data-end=\"1284\"\u003e\u003cmeta charset=\"utf-8\"\u003e- 2 x M20 cable entries for simplified on-site wiring\u003cbr data-start=\"1338\" data-end=\"1341\"\u003e\u003cmeta charset=\"utf-8\"\u003e- Mechanical visual indicator for real-time valve status\u003cbr data-start=\"1398\" data-end=\"1401\"\u003e\u003cmeta charset=\"utf-8\"\u003e- Compatible with actuated ball and butterfly valve setups\u003c\/p\u003e","brand":"Hygienic Valve","offers":[{"title":"Default Title","offer_id":54938520420677,"sku":null,"price":414.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/TrewfitControlsMechanicalLimitSwitchbox_SPDT_250V10A_IP68_2xM20Entries.png?v=1781169852"},{"product_id":"air-torque-service-kit","title":"Air Torque Service Kit (Packs of 5 Available)","description":"\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e options marked “Pack of 5” are supplied as packs of five units, and the price shown is for the full pack.\u003c\/p\u003e\u003ch2\u003eAir Torque Service Kit\u003c\/h2\u003e\n\u003cp\u003eAir Torque Service Kit, your ultimate companion for maintaining optimal performance of your air tools. Crafted with precision engineering, this kit is designed to ensure your tools stay in top-notch condition without any hassle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive set: Includes all necessary components for servicing air tools.\u003c\/li\u003e\n\u003cli\u003eDurable materials: Built to last, with high-quality materials that withstand wear and tear.\u003c\/li\u003e\n\u003cli\u003eEasy to use: Simple instructions make servicing your tools a breeze.\u003c\/li\u003e\n\u003cli\u003eVersatile compatibility: Compatible with a wide range of air tool brands and models.\u003c\/li\u003e\n\u003cli\u003eCost-effective solution: Save money on repairs with regular maintenance using the Air Torque Service Kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep your Air Torque Actuators running smoothly and efficiently with the Air Torque Service Kit.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Valves UK","offers":[{"title":"AT 045U A \/ Standard \/ Pack of 5","offer_id":55807577784645,"sku":"WVAT045UASRK","price":224.95,"currency_code":"GBP","in_stock":true},{"title":"AT 045U A \/ High Temperature \/ Pack of 5","offer_id":55807577817413,"sku":"WVAT045UASRK","price":260.0,"currency_code":"GBP","in_stock":true},{"title":"AT 051U A \/ Standard \/ Pack of 5","offer_id":55807577850181,"sku":"WVAT051UASRK","price":200.0,"currency_code":"GBP","in_stock":true},{"title":"AT 051U A \/ High Temperature \/ Pack of 5","offer_id":55807577882949,"sku":"WVAT051UASRK","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"AT 101U A \/ Standard \/ Pack of 5","offer_id":55807577915717,"sku":"WVAT101UASRK","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"AT 101U A \/ High Temperature \/ Pack of 5","offer_id":55807577948485,"sku":"WVAT101UASRK","price":340.0,"currency_code":"GBP","in_stock":true},{"title":"AT 201U A \/ Standard \/ Pack of 5","offer_id":55807577981253,"sku":"WVAT201UASRK","price":310.0,"currency_code":"GBP","in_stock":true},{"title":"AT 201U A \/ High Temperature \/ Pack of 5","offer_id":55807578014021,"sku":"WVAT201UASRK","price":400.0,"currency_code":"GBP","in_stock":true},{"title":"AT 251U A \/ Standard \/ Pack of 5","offer_id":55807578046789,"sku":"WVAT251UASRK","price":350.0,"currency_code":"GBP","in_stock":true},{"title":"AT 251U A \/ High Temperature \/ Pack of 5","offer_id":55807578079557,"sku":"WVAT251UASRK","price":440.0,"currency_code":"GBP","in_stock":true},{"title":"AT 301U A \/ Standard \/ Pack of 5","offer_id":55807578112325,"sku":"WVAT301UASRK","price":420.0,"currency_code":"GBP","in_stock":true},{"title":"AT 301U A \/ High Temperature \/ Single","offer_id":55807578145093,"sku":"WVAT301UASRK","price":102.0,"currency_code":"GBP","in_stock":true},{"title":"AT 351U A \/ Standard \/ Pack of 5","offer_id":55807578177861,"sku":"WVAT351UASRK","price":440.0,"currency_code":"GBP","in_stock":true},{"title":"AT 351U A \/ High Temperature \/ Single","offer_id":55807578210629,"sku":"WVAT351UASRK","price":146.0,"currency_code":"GBP","in_stock":true},{"title":"AT 401U A \/ Standard \/ Single","offer_id":55807578243397,"sku":"WVAT401UASRK","price":1066.0,"currency_code":"GBP","in_stock":true},{"title":"AT 401U A \/ High Temperature \/ Single","offer_id":55807578276165,"sku":"WVAT401UASRK","price":148.0,"currency_code":"GBP","in_stock":true},{"title":"AT 451U A \/ Standard \/ Single","offer_id":55807578308933,"sku":"WVAT451UASRK","price":136.0,"currency_code":"GBP","in_stock":true},{"title":"AT 451U A \/ High Temperature \/ Single","offer_id":55807578341701,"sku":"WVAT451UASRK","price":204.0,"currency_code":"GBP","in_stock":true},{"title":"AT 501U A \/ Standard \/ Single","offer_id":55807578374469,"sku":"WVAT501UASRK","price":192.0,"currency_code":"GBP","in_stock":true},{"title":"AT 501U A \/ High Temperature \/ Single","offer_id":55807578407237,"sku":"WVAT501UASRK","price":240.0,"currency_code":"GBP","in_stock":true},{"title":"AT 551U A \/ Standard \/ Single","offer_id":55807578440005,"sku":"WVAT551UASRK","price":186.0,"currency_code":"GBP","in_stock":true},{"title":"AT 551U A \/ High Temperature \/ Single","offer_id":55807578472773,"sku":"WVAT551UASRK","price":288.0,"currency_code":"GBP","in_stock":true},{"title":"AT 601U A \/ Standard \/ Single","offer_id":55807578505541,"sku":"WVAT601UASRK","price":202.0,"currency_code":"GBP","in_stock":true},{"title":"AT 601U A \/ High Temperature \/ Single","offer_id":55807578538309,"sku":"WVAT601UASRK","price":384.0,"currency_code":"GBP","in_stock":true},{"title":"AT 651U A \/ Standard \/ Single","offer_id":55807578571077,"sku":"WVAT651UASRK","price":276.0,"currency_code":"GBP","in_stock":true},{"title":"AT 651U A \/ High Temperature \/ Single","offer_id":55807578603845,"sku":"WVAT651UASRK","price":427.0,"currency_code":"GBP","in_stock":true},{"title":"AT 701U A \/ Standard \/ Single","offer_id":55807578636613,"sku":"WVAT701UASRK","price":342.0,"currency_code":"GBP","in_stock":true},{"title":"AT 701U A \/ High Temperature \/ Single","offer_id":55807578669381,"sku":"WVAT701UASRK","price":598.0,"currency_code":"GBP","in_stock":true},{"title":"AT 751U A \/ Standard \/ Single","offer_id":55807578702149,"sku":"WVAT751UASRK","price":342.99,"currency_code":"GBP","in_stock":true},{"title":"AT 751U A \/ High Temperature \/ Single","offer_id":55807578734917,"sku":"WVAT751UASRK","price":599.99,"currency_code":"GBP","in_stock":true},{"title":"AT 801U A \/ Standard \/ Single","offer_id":55807578767685,"sku":"WVAT801UASRK","price":480.0,"currency_code":"GBP","in_stock":true},{"title":"AT 801U A \/ High Temperature \/ Single","offer_id":55807578800453,"sku":"WVAT801UASRK","price":660.0,"currency_code":"GBP","in_stock":true},{"title":"AT 1001U A \/ Standard \/ Single","offer_id":55807578833221,"sku":"WVAT1001UASRK","price":668.0,"currency_code":"GBP","in_stock":true},{"title":"AT 1001U A \/ High Temperature \/ Single","offer_id":55807578865989,"sku":"WVAT1001UASRK","price":810.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AirTorqueServiceKit.jpg?v=1759837765"},{"product_id":"bronze-y-strainer","title":"Bronze Y Strainer (Packs of 5 Available)","description":"\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e options marked “Pack of 5” are supplied as packs of five units, and the price shown is for the full pack.\u003c\/p\u003e\u003cp data-start=\"166\" data-end=\"494\" class=\"\"\u003eThe Bronze Y Strainer is designed to protect valves, pumps, and other downstream equipment by efficiently filtering out debris and particulates from your fluid system. Its compact Y-pattern body allows for low-pressure drop while capturing solids in a removable mesh screen, making maintenance quick and straightforward.\u003c\/p\u003e\n\u003cp data-start=\"496\" data-end=\"810\" class=\"\"\u003eManufactured from high-quality bronze, this strainer offers excellent corrosion resistance, making it ideal for water, steam, air, and non-aggressive fluid applications. Suitable for both horizontal and vertical installations (with flow downward), it's a reliable solution for industrial, marine, and HVAC systems.\u003c\/p\u003e\n\u003chr data-start=\"812\" data-end=\"815\" class=\"\"\u003e\n\u003cp data-start=\"817\" data-end=\"834\" class=\"\"\u003e\u003cstrong data-start=\"817\" data-end=\"834\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"837\" data-end=\"903\" class=\"\"\u003e- Y-pattern design for compact installation and efficient flow\u003c\/p\u003e\n\u003cp data-start=\"906\" data-end=\"957\" class=\"\"\u003e- Bronze body for long-lasting corrosion resistance\u003c\/p\u003e\n\u003cp data-start=\"960\" data-end=\"1017\" class=\"\"\u003e- Removable mesh screen for easy cleaning and maintenance\u003c\/p\u003e\n\u003cp data-start=\"1020\" data-end=\"1081\" class=\"\"\u003e- Suitable for water, steam, air, and light industrial fluids\u003c\/p\u003e\n\u003cp data-start=\"1084\" data-end=\"1137\" class=\"\"\u003e- Horizontal or vertical (downward flow) installation\u003c\/p\u003e\n\u003cp data-start=\"1140\" data-end=\"1195\" class=\"\"\u003e- Ideal for marine, HVAC, and process system protection\u003c\/p\u003e","brand":"Bronze Valves","offers":[{"title":"3\/8\" (Pack of 5)","offer_id":55808661029189,"sku":null,"price":225.0,"currency_code":"GBP","in_stock":true},{"title":"1\/2\" (Pack of 5)","offer_id":55808661061957,"sku":null,"price":240.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\" (Pack of 5)","offer_id":55808661094725,"sku":null,"price":260.0,"currency_code":"GBP","in_stock":true},{"title":"1\" (Pack of 5)","offer_id":55808661127493,"sku":null,"price":275.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/4\" (Pack of 5)","offer_id":55808661160261,"sku":null,"price":325.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/2\" (Pack of 5)","offer_id":55808661193029,"sku":null,"price":375.0,"currency_code":"GBP","in_stock":true},{"title":"2\"","offer_id":55808661225797,"sku":null,"price":105.0,"currency_code":"GBP","in_stock":true},{"title":"2 1\/2\"","offer_id":55808661258565,"sku":null,"price":148.0,"currency_code":"GBP","in_stock":true},{"title":"3\"","offer_id":55808661291333,"sku":null,"price":178.0,"currency_code":"GBP","in_stock":true},{"title":"4\"","offer_id":55808661324101,"sku":null,"price":315.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/BronzeYStrainer_347d7a25-006e-4d6e-83dd-8992e5d11f86.jpg?v=1762513699"},{"product_id":"bronze-2-way-plug-cock-with-gland","title":"Bronze 2-Way Plug Cock with Gland (Packs of 5 Available)","description":"\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e options marked “Pack of 5” are supplied as packs of five units, and the price shown is for the full pack.\u003c\/p\u003e\u003cp data-start=\"202\" data-end=\"514\" class=\"\"\u003eThe Bronze Plug Cock with Gland – 2 Way is a compact and durable shut-off valve designed for simple on\/off control in fluid systems. Featuring a rotating cylindrical plug and gland-packed stem, this valve provides smooth, leak-resistant operation and is ideal for low to medium-pressure applications.\u003c\/p\u003e\n\u003cp data-start=\"516\" data-end=\"784\" class=\"\"\u003eConstructed from corrosion-resistant bronze, it is well-suited for water, air, oil, and non-aggressive fluid services. The gland provides added sealing around the spindle, ensuring safe and reliable performance in industrial, marine, and general-purpose installations.\u003c\/p\u003e\n\u003chr data-start=\"786\" data-end=\"789\" class=\"\"\u003e\n\u003cp data-start=\"791\" data-end=\"808\" class=\"\"\u003e\u003cstrong data-start=\"791\" data-end=\"808\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"811\" data-end=\"862\" class=\"\"\u003e- 2-way design for straightforward flow control\u003c\/p\u003e\n\u003cp data-start=\"865\" data-end=\"915\" class=\"\"\u003e- Gland-packed stem for leak-resistant sealing\u003c\/p\u003e\n\u003cp data-start=\"918\" data-end=\"966\" class=\"\"\u003e- Bronze body for excellent corrosion resistance\u003c\/p\u003e\n\u003cp data-start=\"969\" data-end=\"1007\" class=\"\"\u003e- Compact, robust, and easy to operate\u003c\/p\u003e\n\u003cp data-start=\"1010\" data-end=\"1063\" class=\"\"\u003e- Suitable for water, air, oil, and light-duty fluids\u003c\/p\u003e\n\u003cp data-start=\"1066\" data-end=\"1115\" class=\"\"\u003e- Ideal for marine, industrial, and plant systems\u003c\/p\u003e","brand":"Bronze Valves","offers":[{"title":"1\/2\" (Pack of 5)","offer_id":55808662864197,"sku":null,"price":325.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\" (Pack of 5)","offer_id":55808662896965,"sku":null,"price":490.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808662929733,"sku":null,"price":114.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/4\"","offer_id":55808662962501,"sku":null,"price":144.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/2\"","offer_id":55808662995269,"sku":null,"price":206.0,"currency_code":"GBP","in_stock":true},{"title":"2\"","offer_id":55808663028037,"sku":null,"price":265.0,"currency_code":"GBP","in_stock":true},{"title":"2 1\/2\"","offer_id":55808663060805,"sku":null,"price":465.0,"currency_code":"GBP","in_stock":true},{"title":"3\"","offer_id":55808663093573,"sku":null,"price":616.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/Bronze2-WayPlugCockwithGland_a5f2ac8f-dba8-461f-9658-64f0747da32c.jpg?v=1762513576"},{"product_id":"bronze-3-way-plug-cock-with-gland","title":"Bronze 3-Way Plug Cock with Gland (Packs of 5 Available)","description":"\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e options marked “Pack of 5” are supplied as packs of five units, and the price shown is for the full pack.\u003c\/p\u003e\u003cp data-start=\"202\" data-end=\"577\" class=\"\"\u003eThe Bronze Plug Cock with Gland – 3 Way is designed for directional flow control in multi-line systems. Featuring a rotating plug with three ports, this valve allows for smooth diversion or mixing of fluids, making it ideal for systems requiring switching between different flow paths. The gland-packed stem ensures a secure, leak-resistant seal during operation.\u003c\/p\u003e\n\u003cp data-start=\"579\" data-end=\"879\" class=\"\"\u003eConstructed from high-quality bronze, this 3-way plug cock is corrosion-resistant and built for long-term use in water, oil, air, and other non-aggressive fluid applications. It’s a compact and reliable solution for industrial, marine, and plant room systems where flexible flow control is essential.\u003c\/p\u003e\n\u003chr data-start=\"881\" data-end=\"884\" class=\"\"\u003e\n\u003cp data-start=\"886\" data-end=\"903\" class=\"\"\u003e\u003cstrong data-start=\"886\" data-end=\"903\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"906\" data-end=\"967\" class=\"\"\u003e- 3-way flow control for diverting or mixing applications\u003c\/p\u003e\n\u003cp data-start=\"970\" data-end=\"1019\" class=\"\"\u003e- Gland seal for secure, leak-tight operation\u003c\/p\u003e\n\u003cp data-start=\"1022\" data-end=\"1068\" class=\"\"\u003e- Durable bronze body for corrosion resistance\u003c\/p\u003e\n\u003cp data-start=\"1071\" data-end=\"1107\" class=\"\"\u003e- Simple quarter-turn plug operation\u003c\/p\u003e\n\u003cp data-start=\"1110\" data-end=\"1168\" class=\"\"\u003e- Suitable for water, oil, air, and general-purpose fluids\u003c\/p\u003e\n\u003cp data-start=\"1171\" data-end=\"1215\" class=\"\"\u003e- Ideal for marine, HVAC, and industrial use\u003c\/p\u003e","brand":"Bronze Valves","offers":[{"title":"1\/2\" (Pack of 5)","offer_id":55808663781701,"sku":null,"price":410.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\" (Pack of 5)","offer_id":55808663814469,"sku":null,"price":470.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808663847237,"sku":null,"price":118.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/4\"","offer_id":55808663880005,"sku":null,"price":164.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/2\"","offer_id":55808663912773,"sku":null,"price":245.0,"currency_code":"GBP","in_stock":true},{"title":"2\"","offer_id":55808663945541,"sku":null,"price":318.0,"currency_code":"GBP","in_stock":true},{"title":"2 1\/2\"","offer_id":55808663978309,"sku":null,"price":518.0,"currency_code":"GBP","in_stock":true},{"title":"3\"","offer_id":55808664011077,"sku":null,"price":868.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/Bronze3-WayPlugCockwithGland_3b650109-adab-48da-9dab-ab76fdde9e15.jpg?v=1762513533"},{"product_id":"bronze-flow-indicator-sight-glass-polycarbonate-dome-moplen-ball","title":"Bronze Flow Indicator Sight Glass – Polycarbonate Dome – Moplen Ball","description":"\u003cp data-start=\"271\" data-end=\"580\" class=\"\"\u003eThe Bronze Flow Indicator Sight Glass with a Polycarbonate Dome and Moplen (Polypropylene) Ball offers a clear and reliable visual indication of flow within your system. As fluid passes through the chamber, the floating Moplen ball moves visibly, making it easy to monitor flow status at a glance.\u003c\/p\u003e\n\u003cp data-start=\"582\" data-end=\"914\" class=\"\"\u003eThis indicator combines a robust bronze body for corrosion resistance with a high-impact polycarbonate dome for visibility and durability. The lightweight Moplen ball is chemical-resistant, ensuring compatibility with a wide range of liquids. Ideal for use in water treatment, cooling circuits, and industrial process lines.\u003c\/p\u003e\n\u003chr data-start=\"916\" data-end=\"919\" class=\"\"\u003e\n\u003cp data-start=\"921\" data-end=\"938\" class=\"\"\u003e\u003cstrong data-start=\"921\" data-end=\"938\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"941\" data-end=\"996\" class=\"\"\u003e- Bronze body for strength and corrosion resistance\u003c\/p\u003e\n\u003cp data-start=\"999\" data-end=\"1056\" class=\"\"\u003e- Clear polycarbonate dome for easy visual inspection\u003c\/p\u003e\n\u003cp data-start=\"1059\" data-end=\"1128\" class=\"\"\u003e- Moplen ball for lightweight, chemical-resistant flow indication\u003c\/p\u003e\n\u003cp data-start=\"1131\" data-end=\"1176\" class=\"\"\u003e- Simple installation in horizontal pipelines\u003c\/p\u003e\n\u003cp data-start=\"1179\" data-end=\"1243\" class=\"\"\u003e- Suitable for water, light chemicals, and non-aggressive fluids\u003c\/p\u003e\n\u003cp data-start=\"1246\" data-end=\"1300\" class=\"\"\u003e- Ideal for industrial, HVAC, and utility applications\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"1\/2\"","offer_id":55808666108229,"sku":null,"price":108.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\"","offer_id":55808666140997,"sku":null,"price":124.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808666173765,"sku":null,"price":152.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/BronzeFlowIndicatorSightGlass_PolycarbonateDome_MoplenBall_d6c1b33c-4f85-449b-be4a-5d615ee034c1.jpg?v=1760000889"},{"product_id":"bronze-flow-indicator-sight-glass-hardened-glass-window-moplen-ball","title":"Bronze Flow Indicator Sight Glass – Hardened Glass Window – Moplen Ball","description":"\u003cp data-start=\"284\" data-end=\"626\" class=\"\"\u003eThe Bronze Flow Indicator Sight Glass with a single hardened glass window and Moplen (polypropylene) ball offers durable and reliable visual flow monitoring for a wide range of fluid systems. As media flows through the valve, the highly visible Moplen ball moves freely, providing a simple yet effective indication of active flow.\u003c\/p\u003e\n\u003cp data-start=\"628\" data-end=\"953\" class=\"\"\u003eBuilt with a corrosion-resistant bronze body and a toughened glass viewing window, this unit is suitable for higher temperatures and pressures than standard plastic domes. The Moplen ball adds chemical resistance, making this flow indicator ideal for use in water, light chemical, and general industrial applications.\u003c\/p\u003e\n\u003chr data-start=\"955\" data-end=\"958\" class=\"\"\u003e\n\u003cp data-start=\"960\" data-end=\"977\" class=\"\"\u003e\u003cstrong data-start=\"960\" data-end=\"977\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"980\" data-end=\"1042\" class=\"\"\u003e\u003cstrong data-start=\"980\" data-end=\"1012\"\u003e- \u003c\/strong\u003eHardened glass single window for durable flow visibility\u003c\/p\u003e\n\u003cp data-start=\"1045\" data-end=\"1105\" class=\"\"\u003e- Moplen ball for clear movement and chemical resistance\u003c\/p\u003e\n\u003cp data-start=\"1108\" data-end=\"1168\" class=\"\"\u003e- Bronze body for excellent corrosion and thermal resistance\u003c\/p\u003e\n\u003cp data-start=\"1171\" data-end=\"1228\" class=\"\"\u003e- Reliable visual flow confirmation for pressurised lines\u003c\/p\u003e\n\u003cp data-start=\"1231\" data-end=\"1301\" class=\"\"\u003e- Suitable for water, oils, light chemicals, and non-aggressive fluids\u003c\/p\u003e\n\u003cp data-start=\"1304\" data-end=\"1367\" class=\"\"\u003e- Ideal for process monitoring in industrial and marine systems\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"1\/2\"","offer_id":55808666206533,"sku":null,"price":108.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\"","offer_id":55808666239301,"sku":null,"price":124.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808666272069,"sku":null,"price":142.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/BronzeFlowIndicatorSightGlass_HardenedGlassWindow_MoplenBall_e7cb48d6-3223-4bb8-80f9-c403782f54fb.jpg?v=1760000832"},{"product_id":"bronze-flow-indicator-sight-glass-double-hardened-glass-window-moplen-ball","title":"Bronze Flow Indicator Sight Glass – Double Hardened Glass Window – Moplen Ball","description":"\u003cp data-start=\"291\" data-end=\"672\" class=\"\"\u003eThe Bronze Flow Indicator Sight Glass with double hardened glass windows and a Moplen (polypropylene) ball offers enhanced visibility and long-lasting durability for flow monitoring in demanding systems. As fluid flows through the unit, the Moplen ball moves visibly between both windows, providing a clear and immediate indication of flow from multiple viewing angles.\u003c\/p\u003e\n\u003cp data-start=\"674\" data-end=\"980\" class=\"\"\u003eBuilt with a robust bronze body and dual toughened glass panes, this indicator is resistant to high pressures, elevated temperatures, and mechanical wear. The lightweight, chemically resistant Moplen ball ensures compatibility with a wide range of media, including water, oils, and light chemicals.\u003c\/p\u003e\n\u003chr data-start=\"982\" data-end=\"985\" class=\"\"\u003e\n\u003cp data-start=\"987\" data-end=\"1004\" class=\"\"\u003e\u003cstrong data-start=\"987\" data-end=\"1004\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1007\" data-end=\"1079\" class=\"\"\u003e- Double hardened glass windows for improved visibility and strength\u003c\/p\u003e\n\u003cp data-start=\"1082\" data-end=\"1149\" class=\"\"\u003e- Moplen ball for clear flow indication and chemical resistance\u003c\/p\u003e\n\u003cp data-start=\"1152\" data-end=\"1214\" class=\"\"\u003e- Bronze construction for corrosion and thermal durability\u003c\/p\u003e\n\u003cp data-start=\"1217\" data-end=\"1264\" class=\"\"\u003e- Designed for horizontal pipeline installation\u003c\/p\u003e\n\u003cp data-start=\"1267\" data-end=\"1330\" class=\"\"\u003e- Suitable for water, oils, light chemicals, and process fluids\u003c\/p\u003e\n\u003cp data-start=\"1333\" data-end=\"1392\" class=\"\"\u003e- Ideal for industrial, marine, and plant room applications\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"1\/2\"","offer_id":55808667681093,"sku":null,"price":108.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\"","offer_id":55808667713861,"sku":null,"price":129.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808667746629,"sku":null,"price":142.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/4\"","offer_id":55808667779397,"sku":null,"price":194.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/2\"","offer_id":55808667812165,"sku":null,"price":212.0,"currency_code":"GBP","in_stock":true},{"title":"2\"","offer_id":55808667844933,"sku":null,"price":317.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/BronzeFlowIndicatorSightGlass_DoubleHardenedGlassWindow_MoplenBall_63093c13-0601-47c8-9958-6bf30223c843.jpg?v=1760000720"},{"product_id":"premium-bronze-flow-indicator-precision-crafted-performance","title":"Premium Bronze Flow Indicator","description":"\u003cp data-start=\"315\" data-end=\"652\" class=\"\"\u003eThe Premium Bronze Flow Indicator is engineered for professionals who demand both visual assurance and enduring reliability in their pipeline systems. Manufactured from high-grade, marine-quality bronze, this indicator is designed to perform in harsh environments where strength, corrosion resistance, and longevity are critical.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"993\" class=\"\"\u003eEvery component is selected for performance – from the precision-machined body to the impact-resistant sight glass or smooth-spinning rotor\/ball. Whether for cooling circuits, lubrication lines, or process monitoring, this unit offers real-time flow visibility with exceptional durability and low maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"995\" data-end=\"1072\" class=\"\"\u003eMore than just a component — it's a signal of quality throughout your system.\u003c\/p\u003e\n\u003chr data-start=\"1074\" data-end=\"1077\" class=\"\"\u003e\n\u003cp data-start=\"1079\" data-end=\"1100\" class=\"\"\u003e\u003cstrong data-start=\"1079\" data-end=\"1100\"\u003ePremium Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1103\" data-end=\"1183\" class=\"\"\u003e- Solid bronze construction for unmatched corrosion resistance and longevity\u003c\/p\u003e\n\u003cp data-start=\"1186\" data-end=\"1265\" class=\"\"\u003e- Clear flow visibility through sight glass, rotor, or Moplen ball movement\u003c\/p\u003e\n\u003cp data-start=\"1268\" data-end=\"1330\" class=\"\"\u003e- Built to withstand industrial pressures and temperatures\u003c\/p\u003e\n\u003cp data-start=\"1333\" data-end=\"1374\" class=\"\"\u003e- Low-pressure drop, high flow efficiency\u003c\/p\u003e\n\u003cp data-start=\"1377\" data-end=\"1450\" class=\"\"\u003e- Ideal for marine, chemical, HVAC, and high-spec industrial environments\u003c\/p\u003e\n\u003cp data-start=\"1453\" data-end=\"1525\" class=\"\"\u003e- Designed and built for operators who value performance and reliability\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"1\/2\"","offer_id":55808668696901,"sku":null,"price":194.0,"currency_code":"GBP","in_stock":true},{"title":"3\/4\"","offer_id":55808668729669,"sku":null,"price":238.0,"currency_code":"GBP","in_stock":true},{"title":"1\"","offer_id":55808668762437,"sku":null,"price":280.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/4\"","offer_id":55808668795205,"sku":null,"price":361.0,"currency_code":"GBP","in_stock":true},{"title":"1 1\/2\"","offer_id":55808668827973,"sku":null,"price":396.0,"currency_code":"GBP","in_stock":true},{"title":"2\"","offer_id":55808668860741,"sku":null,"price":574.0,"currency_code":"GBP","in_stock":true},{"title":"2 1\/2\"","offer_id":55808668893509,"sku":null,"price":914.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/PremiumBronzeFlowIndicator.jpg?v=1760000597"},{"product_id":"asco-s353a810-solenoid-valve","title":"Asco S353A810 Dust Collector Solenoid Valves (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003eSupplied as a pack of 5.\u003c\/strong\u003e The price shown is for the full pack of five units.\u003c\/p\u003e\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ASCO S353A810 Dust Collector Solenoid Valve is a 2\/2 normally closed pilot-operated valve specifically engineered for use in dust collector and filtration systems. Designed to provide powerful and efficient air pulse cleaning, this valve ensures optimal system performance and long service life, even in demanding industrial environments.\u003c\/p\u003e\n\u003ch3 data-start=\"923\" data-end=\"942\"\u003e\u003cstrong data-start=\"923\" data-end=\"940\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"945\" data-end=\"985\"\u003e\u003cstrong data-start=\"945\" data-end=\"958\"\u003eFunction:\u003c\/strong\u003e 2\/2 Normally Closed (NC)\u003c\/p\u003e\n\u003cp data-start=\"988\" data-end=\"1019\"\u003e\u003cstrong data-start=\"988\" data-end=\"1002\"\u003eOperation:\u003c\/strong\u003e Pilot operated\u003c\/p\u003e\n\u003cp data-start=\"1022\" data-end=\"1054\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1040\"\u003eBody material:\u003c\/strong\u003e Light alloy\u003c\/p\u003e\n\u003cp data-start=\"1057\" data-end=\"1082\"\u003e\u003cstrong data-start=\"1057\" data-end=\"1074\"\u003eOrifice size:\u003c\/strong\u003e 20 mm\u003c\/p\u003e\n\u003cp data-start=\"1085\" data-end=\"1121\"\u003e\u003cstrong data-start=\"1085\" data-end=\"1099\"\u003eFlow rate:\u003c\/strong\u003e Cv 16.18 \/ Kv 14.00\u003c\/p\u003e\n\u003cp data-start=\"1124\" data-end=\"1150\"\u003e\u003cstrong data-start=\"1124\" data-end=\"1138\"\u003ePort size:\u003c\/strong\u003e 1\/8\" BSPP\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1186\"\u003e\u003cstrong data-start=\"1153\" data-end=\"1176\"\u003eOperating pressure:\u003c\/strong\u003e 0–8 bar\u003c\/p\u003e\n\u003cp data-start=\"1189\" data-end=\"1248\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1211\"\u003eTemperature range:\u003c\/strong\u003e -20°C to +85°C (ambient and fluid)\u003c\/p\u003e\n\u003cp data-start=\"1251\" data-end=\"1331\"\u003e\u003cstrong data-start=\"1251\" data-end=\"1290\"\u003eDesigned for dust collector systems\u003c\/strong\u003e requiring strong air pulse performance\u003c\/p\u003e\n\u003cp data-start=\"1334\" data-end=\"1407\"\u003e\u003cstrong data-start=\"1334\" data-end=\"1363\"\u003eReliable ASCO engineering\u003c\/strong\u003e for industrial air and filtration systems\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811099590981,"sku":null,"price":434.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AscoS353A810DustCollectorSolenoidValves.jpg?v=1759759100"},{"product_id":"asco-e210b156sca8-solenoid-valves","title":"Asco E210B156SCA8-230\/50 Solenoid Valves","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\n\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe ASCO E210B156SCA8 Solenoid Valve (230\/50) is a 2\/2 normally closed pilot-operated valve built for reliable control of air, water, and light oil across a wide range of industrial and process applications. Featuring a brass body with a 32 mm orifice and a 1.5” port size, this valve offers excellent flow capacity and durability in demanding environments.\u003c\/p\u003e\n\u003ch3 data-end=\"903\" data-start=\"884\"\u003e\u003cstrong data-end=\"901\" data-start=\"884\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"946\" data-start=\"906\"\u003e\u003cstrong data-end=\"919\" data-start=\"906\"\u003eFunction:\u003c\/strong\u003e 2\/2 Normally Closed (NC)\u003c\/p\u003e\n\u003cp data-end=\"980\" data-start=\"949\"\u003e\u003cstrong data-end=\"963\" data-start=\"949\"\u003eOperation:\u003c\/strong\u003e Pilot operated\u003c\/p\u003e\n\u003cp data-end=\"1009\" data-start=\"983\"\u003e\u003cstrong data-end=\"1001\" data-start=\"983\"\u003eBody material:\u003c\/strong\u003e Brass\u003c\/p\u003e\n\u003cp data-end=\"1033\" data-start=\"1012\"\u003e\u003cstrong data-end=\"1026\" data-start=\"1012\"\u003ePort size:\u003c\/strong\u003e 1.5”\u003c\/p\u003e\n\u003cp data-end=\"1061\" data-start=\"1036\"\u003e\u003cstrong data-end=\"1053\" data-start=\"1036\"\u003eOrifice size:\u003c\/strong\u003e 32 mm\u003c\/p\u003e\n\u003cp data-end=\"1096\" data-start=\"1064\"\u003e\u003cstrong data-end=\"1087\" data-start=\"1064\"\u003eFace-to-face (F2F):\u003c\/strong\u003e 111 mm\u003c\/p\u003e\n\u003cp data-end=\"1133\" data-start=\"1099\"\u003e\u003cstrong data-end=\"1109\" data-start=\"1099\"\u003eMedia:\u003c\/strong\u003e Air, water, light oil\u003c\/p\u003e\n\u003cp data-end=\"1164\" data-start=\"1136\"\u003e\u003cstrong data-end=\"1148\" data-start=\"1136\"\u003eVoltage:\u003c\/strong\u003e 230V AC, 50Hz\u003c\/p\u003e\n\u003cp data-end=\"1224\" data-start=\"1167\"\u003e\u003cstrong data-end=\"1189\" data-start=\"1167\"\u003eHigh flow capacity\u003c\/strong\u003e for general service applications\u003c\/p\u003e\n\u003cp data-end=\"1271\" data-start=\"1227\"\u003e\u003cstrong data-end=\"1269\" data-start=\"1227\"\u003eDurable and reliable ASCO construction\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811102409029,"sku":null,"price":359.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AscoE210B156SCA8-230_50SolenoidValves.jpg?v=1759760651"},{"product_id":"asco-egsce040800202-230-50","title":"Asco EGSCE040B002D02.230\/50 Solenoid Valve","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"26\" data-end=\"417\"\u003eThe ASCO EGSCE040B002D02.230\/50 Solenoid Valve is a direct-acting 2-way normally closed valve designed for the safe and efficient control of combustible gases in industrial and commercial systems. Built with a robust aluminium body and NBR sealing, this valve ensures long-lasting durability, reliable sealing, and dependable operation in low-pressure gas applications.\u003c\/p\u003e\n\u003ch3 data-start=\"986\" data-end=\"1005\"\u003e\u003cstrong data-start=\"986\" data-end=\"1003\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1008\" data-end=\"1048\"\u003e\u003cstrong data-start=\"1008\" data-end=\"1021\"\u003eFunction:\u003c\/strong\u003e 2\/2 Normally Closed (NC)\u003c\/p\u003e\n\u003cp data-start=\"1051\" data-end=\"1081\"\u003e\u003cstrong data-start=\"1051\" data-end=\"1065\"\u003eOperation:\u003c\/strong\u003e Direct acting\u003c\/p\u003e\n\u003cp data-start=\"1084\" data-end=\"1114\"\u003e\u003cstrong data-start=\"1084\" data-end=\"1102\"\u003eBody material:\u003c\/strong\u003e Aluminium\u003c\/p\u003e\n\u003cp data-start=\"1117\" data-end=\"1151\"\u003e\u003cstrong data-start=\"1117\" data-end=\"1135\"\u003eSeal material:\u003c\/strong\u003e NBR (Nitrile)\u003c\/p\u003e\n\u003cp data-start=\"1154\" data-end=\"1174\"\u003e\u003cstrong data-start=\"1154\" data-end=\"1168\"\u003ePort size:\u003c\/strong\u003e G1”\u003c\/p\u003e\n\u003cp data-start=\"1177\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1177\" data-end=\"1194\"\u003eOrifice size:\u003c\/strong\u003e 23.8 mm\u003c\/p\u003e\n\u003cp data-start=\"1207\" data-end=\"1247\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1233\"\u003eDifferential pressure:\u003c\/strong\u003e 0–0.086 bar\u003c\/p\u003e\n\u003cp data-start=\"1250\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1250\" data-end=\"1260\"\u003eMedia:\u003c\/strong\u003e Combustible gas (e.g., natural gas, LPG)\u003c\/p\u003e\n\u003cp data-start=\"1250\" data-end=\"1303\"\u003e\u003cstrong data-start=\"1306\" data-end=\"1318\"\u003eVoltage:\u003c\/strong\u003e 230V AC, 50Hz\u003c\/p\u003e\n\u003cp data-start=\"1337\" data-end=\"1374\"\u003e\u003cstrong data-start=\"1337\" data-end=\"1359\"\u003eTemperature range:\u003c\/strong\u003e 0°C to +60°C\u003c\/p\u003e\n\u003cp data-start=\"1377\" data-end=\"1432\"\u003e\u003cstrong data-start=\"1377\" data-end=\"1430\"\u003eReliable ASCO design for gas control applications\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811109159237,"sku":null,"price":201.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AscoEGSCE040B002D02.230_50SolenoidValve.jpg?v=1759753223"},{"product_id":"asco-e290a385","title":"Asco E290A385 Pressure Operated Solenoid Valves","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ASCO E290A385 Pressure Operated Solenoid Valve is part of the renowned E290 Series, a range of 2\/2 normally closed piston-type solenoid valves engineered for precise control of both neutral and corrosive fluids. This high-performance valve features a robust bronze body, offering excellent resistance to wear and corrosion, while ensuring smooth operation in demanding process environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1170\" data-start=\"1151\"\u003e\u003cstrong data-end=\"1168\" data-start=\"1151\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1223\" data-start=\"1173\"\u003e\u003cstrong data-end=\"1182\" data-start=\"1173\"\u003eType:\u003c\/strong\u003e 2\/2 Normally Closed, Pressure Operated\u003c\/p\u003e\n\u003cp data-end=\"1304\" data-start=\"1226\"\u003e\u003cstrong data-end=\"1244\" data-start=\"1226\"\u003eBody Material:\u003c\/strong\u003e Bronze (available in stainless steel for corrosive media)\u003c\/p\u003e\n\u003cp data-end=\"1375\" data-start=\"1307\"\u003e\u003cstrong data-end=\"1318\" data-start=\"1307\"\u003eDesign:\u003c\/strong\u003e Piston-type operator with fluid entry under valve disc\u003c\/p\u003e\n\u003cp data-end=\"1446\" data-start=\"1378\"\u003e\u003cstrong data-end=\"1391\" data-start=\"1378\"\u003eFunction:\u003c\/strong\u003e High flow, smooth operation, water hammer prevention\u003c\/p\u003e\n\u003cp data-end=\"1521\" data-start=\"1449\"\u003e\u003cstrong data-end=\"1465\" data-start=\"1449\"\u003ePerformance:\u003c\/strong\u003e High sealing integrity with a reinforced stuffing box\u003c\/p\u003e\n\u003cp data-end=\"1606\" data-start=\"1524\"\u003e\u003cstrong data-end=\"1541\" data-start=\"1524\"\u003eApplications:\u003c\/strong\u003e Neutral and corrosive fluid control, proportional flow systems\u003c\/p\u003e\n\u003cp data-end=\"1700\" data-start=\"1609\"\u003e\u003cstrong data-end=\"1634\" data-start=\"1609\"\u003eOptional integration:\u003c\/strong\u003e Compatible with ASCO control modules for proportional actuation\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811110043973,"sku":null,"price":158.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AscoE290A385PressureOperatedSolenoidValves.jpg?v=1759749011"},{"product_id":"asco-sce210c093-230-50","title":"Asco SCE210C093.230\/50 Solenoid Valve","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ASCO SCE210C093.230\/50 Solenoid Valve is a 2\/2 normally closed pilot-operated valve designed for efficient and reliable control of air, gas, and fluid media in industrial systems. Constructed with a durable brass body and NBR (nitrile) resilient seals, this valve ensures dependable sealing performance and resistance to wear, even under continuous operation.\u003c\/p\u003e\n\u003cp data-start=\"899\" data-end=\"918\"\u003e\u003cstrong data-start=\"899\" data-end=\"916\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"921\" data-end=\"961\"\u003e\u003cstrong data-start=\"921\" data-end=\"934\"\u003eFunction:\u003c\/strong\u003e 2\/2 Normally Closed (NC)\u003c\/p\u003e\n\u003cp data-start=\"964\" data-end=\"995\"\u003e\u003cstrong data-start=\"964\" data-end=\"978\"\u003eOperation:\u003c\/strong\u003e Pilot operated\u003c\/p\u003e\n\u003cp data-start=\"998\" data-end=\"1024\"\u003e\u003cstrong data-start=\"998\" data-end=\"1016\"\u003eBody material:\u003c\/strong\u003e Brass\u003c\/p\u003e\n\u003cp data-start=\"1027\" data-end=\"1061\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1045\"\u003eSeal material:\u003c\/strong\u003e NBR (nitrile)\u003c\/p\u003e\n\u003cp data-start=\"1064\" data-end=\"1089\"\u003e\u003cstrong data-start=\"1064\" data-end=\"1081\"\u003eOrifice size:\u003c\/strong\u003e 16 mm\u003c\/p\u003e\n\u003cp data-start=\"1092\" data-end=\"1126\"\u003e\u003cstrong data-start=\"1092\" data-end=\"1112\"\u003ePort connection:\u003c\/strong\u003e 3\/8\" (DN10)\u003c\/p\u003e\n\u003cp data-start=\"1129\" data-end=\"1151\"\u003e\u003cstrong data-start=\"1129\" data-end=\"1141\"\u003eVoltage:\u003c\/strong\u003e 230V AC\u003c\/p\u003e\n\u003cp data-start=\"1154\" data-end=\"1185\"\u003e\u003cstrong data-start=\"1154\" data-end=\"1176\"\u003ePower consumption:\u003c\/strong\u003e 10.5 W\u003c\/p\u003e\n\u003cp data-start=\"1188\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1188\" data-end=\"1203\"\u003eCoil class:\u003c\/strong\u003e F\u003c\/p\u003e\n\u003cp data-start=\"1210\" data-end=\"1239\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1232\"\u003eProtection rating:\u003c\/strong\u003e IP65\u003c\/p\u003e\n\u003cp data-start=\"1242\" data-end=\"1294\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1292\"\u003eReliable ASCO design for long-term performance\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811114238277,"sku":null,"price":141.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AscoSCE210C093.230_50SolenoidValve.jpg?v=1759749653"},{"product_id":"asco-sce210c03323050","title":"ASCO SCE210C033.230\/50 Solenoid Valve","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ASCO SCE210C033.230\/50 Solenoid Valve is a 2\/2 normally open (NO) valve designed for reliable control of air and gas in industrial and automation systems. Featuring a brass body and precision 16 mm orifice, it provides excellent durability and resistance to corrosion while maintaining efficient flow performance. With a flow coefficient (Kv) of 2.6 m³\/h (43 l\/min), this valve ensures smooth operation and dependable switching for a wide range of pneumatic and gas-handling applications.\u003c\/p\u003e\n\u003cp data-start=\"960\" data-end=\"979\"\u003e\u003cstrong data-start=\"960\" data-end=\"977\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"982\" data-end=\"1020\"\u003e\u003cstrong data-start=\"982\" data-end=\"995\"\u003eFunction:\u003c\/strong\u003e 2\/2 Normally Open (NO)\u003c\/p\u003e\n\u003cp data-start=\"1023\" data-end=\"1057\"\u003e\u003cstrong data-start=\"1023\" data-end=\"1037\"\u003eOperation:\u003c\/strong\u003e Solenoid operated\u003c\/p\u003e\n\u003cp data-start=\"1060\" data-end=\"1086\"\u003e\u003cstrong data-start=\"1060\" data-end=\"1078\"\u003eBody material:\u003c\/strong\u003e Brass\u003c\/p\u003e\n\u003cp data-start=\"1089\" data-end=\"1117\"\u003e\u003cstrong data-start=\"1089\" data-end=\"1109\"\u003ePort connection:\u003c\/strong\u003e G3\/8\"\u003c\/p\u003e\n\u003cp data-start=\"1120\" data-end=\"1145\"\u003e\u003cstrong data-start=\"1120\" data-end=\"1137\"\u003eOrifice size:\u003c\/strong\u003e 16 mm\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1191\"\u003e\u003cstrong data-start=\"1148\" data-end=\"1169\"\u003eFlow coefficient:\u003c\/strong\u003e 2.6 m³\/h (43 l\/min)\u003c\/p\u003e\n\u003cp data-start=\"1194\" data-end=\"1215\"\u003e\u003cstrong data-start=\"1194\" data-end=\"1204\"\u003eMedia:\u003c\/strong\u003e Air, gas\u003c\/p\u003e\n\u003cp data-start=\"1218\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1218\" data-end=\"1230\"\u003eVoltage:\u003c\/strong\u003e 230V AC\u003c\/p\u003e\n\u003cp data-start=\"1243\" data-end=\"1274\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1265\"\u003ePower consumption:\u003c\/strong\u003e 10.5 W\u003c\/p\u003e\n\u003cp data-start=\"1277\" data-end=\"1329\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1327\"\u003eReliable ASCO build quality for industrial use\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55811122757957,"sku":null,"price":167.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOSCE210C033.230_50SolenoidValve.jpg?v=1759748615"},{"product_id":"aventics-g652ar004ga00h0-g-1-2-pneumatic-regulator","title":"Aventics G652AR004GA00H0 G 1\/2 Pneumatic Regulator (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003eSupplied as a pack of 5.\u003c\/strong\u003e The price shown is for the full pack of five units.\u003c\/p\u003e\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"429\" data-start=\"26\"\u003eThe Emerson Aventics G 1\/2 Pneumatic Regulator (651\/652 Series) is a high-performance air preparation component designed to provide precise pressure control across a wide range of industrial and automation applications. With an adjustable output pressure range of 0.5 to 10 bar and a maximum input of 16 bar, this regulator delivers excellent flow characteristics, stability, and accuracy.\u003c\/p\u003e\n\u003ch3 data-end=\"1065\" data-start=\"1046\"\u003e\u003cstrong data-end=\"1063\" data-start=\"1046\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1111\" data-start=\"1068\"\u003e\u003cstrong data-end=\"1087\" data-start=\"1068\"\u003ePressure range:\u003c\/strong\u003e 0.5–10 bar adjustable\u003c\/p\u003e\n\u003cp data-end=\"1150\" data-start=\"1114\"\u003e\u003cstrong data-end=\"1141\" data-start=\"1114\"\u003eMaximum input pressure:\u003c\/strong\u003e 16 bar\u003c\/p\u003e\n\u003cp data-end=\"1178\" data-start=\"1153\"\u003e\u003cstrong data-end=\"1169\" data-start=\"1153\"\u003eThread size:\u003c\/strong\u003e G 1\/2\"\u003c\/p\u003e\n\u003cp data-end=\"1228\" data-start=\"1181\"\u003e\u003cstrong data-end=\"1199\" data-start=\"1181\"\u003eHigh flow rate\u003c\/strong\u003e for demanding applications\u003c\/p\u003e\n\u003cp data-end=\"1278\" data-start=\"1231\"\u003e\u003cstrong data-end=\"1265\" data-start=\"1231\"\u003eModular or individual mounting\u003c\/strong\u003e capability\u003c\/p\u003e\n\u003cp data-end=\"1323\" data-start=\"1281\"\u003e\u003cstrong data-end=\"1321\" data-start=\"1281\"\u003eLow-profile pressure gauge (bar\/PSI)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1384\" data-start=\"1326\"\u003e\u003cstrong data-end=\"1348\" data-start=\"1326\"\u003eTemperature range:\u003c\/strong\u003e -40°C to +80°C (optional version)\u003c\/p\u003e\n\u003cp data-end=\"1464\" data-start=\"1387\"\u003e\u003cstrong data-end=\"1462\" data-start=\"1387\"\u003eAvailable with relieving, non-relieving, or internal flow check options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1513\" data-start=\"1467\"\u003e\u003cstrong data-end=\"1511\" data-start=\"1467\"\u003eReliable ASCO 651\/652 Series performance\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55833494028613,"sku":null,"price":359.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/AventicsG652AR004GA00H0G1_2PneumaticRegulator..jpg?v=1759743621"},{"product_id":"asco-sce210b156-solenoid-valve","title":"ASCO SCE210B156 Solenoid Valve","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"436\" data-start=\"26\"\u003eThe ASCO SCE210B156 Solenoid Valve is a robust and high-capacity 2\/2 normally closed pilot-operated valve, designed for reliable flow control across air, inert gas, light oil, and water applications. Featuring a brass body and NBR sealing, this valve ensures dependable performance, resistance to corrosion, and long operational life, making it suitable for a wide variety of industrial uses.\u003c\/p\u003e\n\u003cp data-end=\"1060\" data-start=\"1041\"\u003e\u003cstrong data-end=\"1058\" data-start=\"1041\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1089\" data-start=\"1063\"\u003e\u003cstrong data-end=\"1081\" data-start=\"1063\"\u003eBody material:\u003c\/strong\u003e Brass\u003c\/p\u003e\n\u003cp data-end=\"1116\" data-start=\"1092\"\u003e\u003cstrong data-end=\"1110\" data-start=\"1092\"\u003eSeal material:\u003c\/strong\u003e NBR\u003c\/p\u003e\n\u003cp data-end=\"1172\" data-start=\"1119\"\u003e\u003cstrong data-end=\"1134\" data-start=\"1119\"\u003eValve type:\u003c\/strong\u003e 2\/2 Normally Closed, pilot-operated\u003c\/p\u003e\n\u003cp data-end=\"1220\" data-start=\"1175\"\u003e\u003cstrong data-end=\"1185\" data-start=\"1175\"\u003eMedia:\u003c\/strong\u003e Air, inert gas, light oil, water\u003c\/p\u003e\n\u003cp data-end=\"1248\" data-start=\"1223\"\u003e\u003cstrong data-end=\"1246\" data-start=\"1223\"\u003eOperating pressure: \u003c\/strong\u003eAir: 0–5 bar | Water: 0–5 bar | Light oil: 0–3 bar\u003c\/p\u003e\n\u003cp data-end=\"1343\" data-start=\"1316\"\u003e\u003cstrong data-end=\"1333\" data-start=\"1316\"\u003eOrifice size:\u003c\/strong\u003e DN32 mm\u003c\/p\u003e\n\u003cp data-end=\"1381\" data-start=\"1346\"\u003e\u003cstrong data-end=\"1360\" data-start=\"1346\"\u003ePipe size:\u003c\/strong\u003e Rp 1 1\/2 (ISO 7\/1)\u003c\/p\u003e\n\u003cp data-end=\"1443\" data-start=\"1384\"\u003e\u003cstrong data-end=\"1399\" data-start=\"1384\"\u003eCoil class:\u003c\/strong\u003e F | \u003cstrong data-end=\"1416\" data-start=\"1404\"\u003eVoltage:\u003c\/strong\u003e 24 VDC | \u003cstrong data-end=\"1436\" data-start=\"1426\"\u003ePower:\u003c\/strong\u003e 23 W\u003c\/p\u003e\n\u003cp data-end=\"1493\" data-start=\"1446\"\u003e\u003cstrong data-end=\"1476\" data-start=\"1446\"\u003eAmbient temperature range:\u003c\/strong\u003e -20°C to +50°C\u003c\/p\u003e\n\u003cp data-end=\"1541\" data-start=\"1496\"\u003e\u003cstrong data-end=\"1524\" data-start=\"1496\"\u003eFluid temperature range:\u003c\/strong\u003e -20°C to +85°C\u003c\/p\u003e\n\u003cp data-end=\"1564\" data-start=\"1544\"\u003e\u003cstrong data-end=\"1555\" data-start=\"1544\"\u003eWeight:\u003c\/strong\u003e 2.8 kg\u003c\/p\u003e\n\u003cp data-end=\"1602\" data-start=\"1567\"\u003e\u003cstrong data-end=\"1588\" data-start=\"1567\"\u003eElectrical entry:\u003c\/strong\u003e Cable gland\u003c\/p\u003e\n\u003cp data-end=\"1675\" data-start=\"1605\"\u003e\u003cstrong data-end=\"1622\" data-start=\"1605\"\u003eManufacturer:\u003c\/strong\u003e ASCO – a trusted name in solenoid valve technology\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55833507463493,"sku":null,"price":329.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOSCE210B156SolenoidValve.jpg?v=1759744127"},{"product_id":"asco-egsce040a024-230-50-solenoid-valve","title":"ASCO EGSCE040A024.230\/50 Solenoid Valve","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 data-start=\"26\" data-end=\"405\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe ASCO EGSCE040A024.230\/50 Solenoid Valve is a direct-acting 2-way normally closed valve engineered for the safe and efficient control of combustible gases. With a G1\" port size and a 23.8 mm orifice, this valve is designed for low-pressure applications, offering precise flow control and excellent reliability across gas systems.\u003c\/p\u003e\n\u003cp data-end=\"1017\" data-start=\"998\"\u003e\u003cstrong data-end=\"1015\" data-start=\"998\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1062\" data-start=\"1020\"\u003e\u003cstrong data-end=\"1033\" data-start=\"1020\"\u003eFunction:\u003c\/strong\u003e 2-way normally closed (NC)\u003c\/p\u003e\n\u003cp data-end=\"1095\" data-start=\"1065\"\u003e\u003cstrong data-end=\"1079\" data-start=\"1065\"\u003eOperation:\u003c\/strong\u003e Direct acting\u003c\/p\u003e\n\u003cp data-end=\"1128\" data-start=\"1098\"\u003e\u003cstrong data-end=\"1116\" data-start=\"1098\"\u003eBody material:\u003c\/strong\u003e Aluminium\u003c\/p\u003e\n\u003cp data-end=\"1165\" data-start=\"1131\"\u003e\u003cstrong data-end=\"1149\" data-start=\"1131\"\u003eSeal material:\u003c\/strong\u003e NBR (nitrile)\u003c\/p\u003e\n\u003cp data-end=\"1188\" data-start=\"1168\"\u003e\u003cstrong data-end=\"1182\" data-start=\"1168\"\u003ePort size:\u003c\/strong\u003e G1\"\u003c\/p\u003e\n\u003cp data-end=\"1218\" data-start=\"1191\"\u003e\u003cstrong data-end=\"1208\" data-start=\"1191\"\u003eOrifice size:\u003c\/strong\u003e 23.8 mm\u003c\/p\u003e\n\u003cp data-end=\"1249\" data-start=\"1221\"\u003e\u003cstrong data-end=\"1231\" data-start=\"1221\"\u003eMedia:\u003c\/strong\u003e Combustible gas\u003c\/p\u003e\n\u003cp data-end=\"1292\" data-start=\"1252\"\u003e\u003cstrong data-end=\"1278\" data-start=\"1252\"\u003eDifferential pressure:\u003c\/strong\u003e 0–0.086 bar\u003c\/p\u003e\n\u003cp data-end=\"1338\" data-start=\"1295\"\u003e\u003cstrong data-end=\"1323\" data-start=\"1295\"\u003eFluid temperature range:\u003c\/strong\u003e 0°C to +60°C\u003c\/p\u003e\n\u003cp data-end=\"1369\" data-start=\"1341\"\u003e\u003cstrong data-end=\"1353\" data-start=\"1341\"\u003eVoltage:\u003c\/strong\u003e 230V AC, 50Hz\u003c\/p\u003e\n\u003cp data-end=\"1424\" data-start=\"1372\"\u003e\u003cstrong data-end=\"1401\" data-start=\"1372\"\u003eReliable ASCO performance\u003c\/strong\u003e for gas applications\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55833562710341,"sku":null,"price":386.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOEGSCE040A024.230_50SolenoidValve.jpg?v=1759744604"},{"product_id":"asco-e290b010-pressure-operated-valves","title":"ASCO E290B010 Pressure Operated Valves","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"26\" data-end=\"405\"\u003eThe ASCO E290B010 Pressure Operated Valve is part of the trusted ASCO E290 Series, a range of 2\/2 normally closed piston-operated valves designed for precise and reliable control of neutral and aggressive fluids. This model combines robust construction with advanced engineering to deliver dependable performance in high-pressure and demanding process applications.\u003c\/p\u003e\n\u003cp data-start=\"1076\" data-end=\"1095\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1093\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1098\" data-end=\"1134\"\u003e\u003cstrong data-start=\"1098\" data-end=\"1107\"\u003eType:\u003c\/strong\u003e 2\/2 Normally Closed (NC)\u003c\/p\u003e\n\u003cp data-start=\"1137\" data-end=\"1184\"\u003e\u003cstrong data-start=\"1137\" data-end=\"1151\"\u003eOperation:\u003c\/strong\u003e Pressure operated, piston type\u003c\/p\u003e\n\u003cp data-start=\"1187\" data-end=\"1262\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1205\"\u003eBody material:\u003c\/strong\u003e Bronze or stainless steel (depending on specification)\u003c\/p\u003e\n\u003cp data-start=\"1265\" data-end=\"1311\"\u003e\u003cstrong data-start=\"1265\" data-end=\"1276\"\u003eDesign:\u003c\/strong\u003e Fluid entry under the valve disc\u003c\/p\u003e\n\u003cp data-start=\"1314\" data-end=\"1355\"\u003e\u003cstrong data-start=\"1314\" data-end=\"1332\"\u003eHigh flow rate\u003c\/strong\u003e and stable operation\u003c\/p\u003e\n\u003cp data-start=\"1358\" data-end=\"1409\"\u003e\u003cstrong data-start=\"1358\" data-end=\"1385\"\u003eWater hammer prevention\u003c\/strong\u003e for system protection\u003c\/p\u003e\n\u003cp data-start=\"1412\" data-end=\"1471\"\u003e\u003cstrong data-start=\"1412\" data-end=\"1445\"\u003eHigh-performance stuffing box\u003c\/strong\u003e for leak-free operation\u003c\/p\u003e\n\u003cp data-start=\"1474\" data-end=\"1524\"\u003e\u003cstrong data-start=\"1474\" data-end=\"1493\"\u003eSuitable media:\u003c\/strong\u003e Neutral and corrosive fluids\u003c\/p\u003e\n\u003cp data-start=\"1527\" data-end=\"1614\"\u003e\u003cstrong data-start=\"1527\" data-end=\"1541\"\u003eIdeal for:\u003c\/strong\u003e Process automation, fluid handling, water and chemical control systems\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55837150937413,"sku":null,"price":157.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOE290B010PressureOperatedValves.jpg?v=1759753585"},{"product_id":"asco-34203086-filter-regulator","title":"ASCO 34203086 Filter Regulator (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003eSupplied as a pack of 5.\u003c\/strong\u003e The price shown is for the full pack of five units.\u003c\/p\u003e\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"405\" data-start=\"26\"\u003eThe ASCO 34203086 Filter Regulator from the 342 Series is a high-performance, combined air preparation unit designed to deliver clean, dry, and precisely regulated air for pneumatic systems. With a G1\/4” port connection and a controlled pressure range of 0.5 to 10 bar, this compact yet efficient filter regulator ensures consistent downstream pressure and optimal air quality for industrial and automation applications.\u003c\/p\u003e\n\u003ch3 data-end=\"960\" data-start=\"941\"\u003e\u003cstrong data-end=\"958\" data-start=\"941\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"992\" data-start=\"963\"\u003e\u003cstrong data-end=\"974\" data-start=\"963\"\u003eSeries:\u003c\/strong\u003e ASCO 342 Series\u003c\/p\u003e\n\u003cp data-end=\"1040\" data-start=\"995\"\u003e\u003cstrong data-end=\"1008\" data-start=\"995\"\u003eFunction:\u003c\/strong\u003e Combined Filter and Regulator\u003c\/p\u003e\n\u003cp data-end=\"1065\" data-start=\"1043\"\u003e\u003cstrong data-end=\"1057\" data-start=\"1043\"\u003ePort size:\u003c\/strong\u003e G1\/4”\u003c\/p\u003e\n\u003cp data-end=\"1116\" data-start=\"1068\"\u003e\u003cstrong data-end=\"1087\" data-start=\"1068\"\u003ePressure range:\u003c\/strong\u003e 0.5 to 10 bar (controlled)\u003c\/p\u003e\n\u003cp data-end=\"1146\" data-start=\"1119\"\u003e\u003cstrong data-end=\"1133\" data-start=\"1119\"\u003eFlow rate:\u003c\/strong\u003e 1800 L\/min\u003c\/p\u003e\n\u003cp data-end=\"1191\" data-start=\"1149\"\u003e\u003cstrong data-end=\"1159\" data-start=\"1149\"\u003eMedia:\u003c\/strong\u003e Compressed air, neutral gases\u003c\/p\u003e\n\u003cp data-end=\"1235\" data-start=\"1194\"\u003e\u003cstrong data-end=\"1214\" data-start=\"1194\"\u003eBody dimensions:\u003c\/strong\u003e 112 × 105 × 251 mm\u003c\/p\u003e\n\u003cp data-end=\"1266\" data-start=\"1238\"\u003e\u003cstrong data-end=\"1256\" data-start=\"1238\"\u003eBowl capacity:\u003c\/strong\u003e 114 cm³\u003c\/p\u003e\n\u003cp data-end=\"1333\" data-start=\"1269\"\u003e\u003cstrong data-end=\"1299\" data-start=\"1269\"\u003eDurable and compact design\u003c\/strong\u003e for space-limited installations\u003c\/p\u003e\n\u003cp data-end=\"1401\" data-start=\"1336\"\u003e\u003cstrong data-end=\"1368\" data-start=\"1336\"\u003eEnsures clean, regulated air\u003c\/strong\u003e to protect pneumatic equipment\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55838946591045,"sku":null,"price":374.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCO34203086FilterRegulator.jpg?v=1759761332"},{"product_id":"asco-x210525720102e7-solenoid-valve","title":"ASCO X210525720102E7 Solenoid Valve 6DC","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 data-start=\"26\" data-end=\"405\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch2 data-start=\"30\" data-end=\"498\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); text-decoration: underline;\"\u003e\u003cstrong\u003eIncludes Plug Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"707\" data-end=\"726\"\u003e\u003cstrong data-start=\"707\" data-end=\"724\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"729\" data-end=\"813\"\u003e\u003cstrong data-start=\"729\" data-end=\"754\"\u003ePilot-operated design\u003c\/strong\u003e for efficient flow control in high-pressure applications\u003c\/p\u003e\n\u003cp data-start=\"816\" data-end=\"898\"\u003e\u003cstrong data-start=\"816\" data-end=\"840\"\u003eDurable construction\u003c\/strong\u003e ensuring long-term reliability and corrosion resistance\u003c\/p\u003e\n\u003cp data-start=\"901\" data-end=\"983\"\u003e\u003cstrong data-start=\"901\" data-end=\"924\"\u003eFast response times\u003c\/strong\u003e with consistent operation in both on\/off control systems\u003c\/p\u003e\n\u003cp data-start=\"986\" data-end=\"1060\"\u003e\u003cstrong data-start=\"986\" data-end=\"1004\"\u003eCompact design\u003c\/strong\u003e allowing easy integration into new or existing setups\u003c\/p\u003e\n\u003cp data-start=\"1063\" data-end=\"1133\"\u003e\u003cstrong data-start=\"1063\" data-end=\"1085\"\u003eEngineered by ASCO\u003c\/strong\u003e, a global leader in solenoid valve technology\u003c\/p\u003e\n\u003cp data-start=\"1135\" data-end=\"1381\"\u003eWhether you’re managing pneumatic systems, fluid control circuits, or automated process lines, the ASCO X210525720102E7 Solenoid Valve 6DC offers the proven reliability and performance expected from one of the industry’s most trusted manufacturers.\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55973897732421,"sku":null,"price":154.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/X210525720102E7_ede9471f-2bd2-4153-888f-9a98cd62127b.jpg?v=1760540876"},{"product_id":"asco-x210525720002e7-solenoid-valve","title":"ASCO X210525720002E7 Solenoid Valve 6DC","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 data-start=\"26\" data-end=\"405\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"733\" data-start=\"30\"\u003eThe Asco X210525720002E7 Solenoid Valve 6DC delivers precise, dependable control for a wide range of industrial applications. Built for high performance and reliability, this solenoid valve is engineered to handle demanding environments with consistent operation. Its compact design allows for flexible installation in tight spaces, while the robust construction ensures long service life even under continuous use. The Asco X210525720002E7 is ideal for controlling air, inert gases, and light liquids, offering quick response times and energy-efficient operation. Trusted by engineers worldwide, Asco solenoid valves are known for their superior sealing, durability, and low maintenance requirements.\u003c\/p\u003e\n\u003ch2 data-end=\"498\" data-start=\"30\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); text-decoration: underline;\"\u003e\u003cstrong\u003eNo Plug Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"754\" data-start=\"735\"\u003e\u003cstrong data-end=\"752\" data-start=\"735\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"822\" data-start=\"757\"\u003e\u003cstrong data-end=\"779\" data-start=\"757\"\u003eReliable operation\u003c\/strong\u003e under varying pressures and temperatures\u003c\/p\u003e\n\u003cp data-end=\"877\" data-start=\"825\"\u003e\u003cstrong data-end=\"847\" data-start=\"825\"\u003eFast response time\u003c\/strong\u003e for precise process control\u003c\/p\u003e\n\u003cp data-end=\"944\" data-start=\"880\"\u003e\u003cstrong data-end=\"912\" data-start=\"880\"\u003eEnergy-efficient coil design\u003c\/strong\u003e for reduced power consumption\u003c\/p\u003e\n\u003cp data-end=\"1022\" data-start=\"947\"\u003e\u003cstrong data-end=\"976\" data-start=\"947\"\u003eCompact and durable build\u003c\/strong\u003e suited to industrial and automation systems\u003c\/p\u003e\n\u003cp data-end=\"1082\" data-start=\"1025\"\u003e\u003cstrong data-end=\"1080\" data-start=\"1025\"\u003eCompatible with air, inert gases, and light liquids\u003c\/strong\u003e\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55973904056645,"sku":null,"price":159.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOX210525720002E7SolenoidValve.jpg?v=1760541034"},{"product_id":"asco-x210525720102f3-solenoid-valve","title":"ASCO X210525720102F3 Solenoid Valve 12DC","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 data-start=\"26\" data-end=\"405\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"30\" data-end=\"498\"\u003eThe ASCO X210525720102F3 Solenoid Valve 12DC is designed for dependable operation and long service life across a wide range of industrial applications. Built with precision and durability in mind, this ASCO Solenoid Valve delivers reliable fluid control performance even in demanding environments. Operating on a 12 VDC supply, it ensures low power consumption and quick response times, making it ideal for automation systems requiring precise actuation.\u003c\/p\u003e\n\u003ch2 data-start=\"30\" data-end=\"498\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); text-decoration: underline;\"\u003e\u003cstrong\u003eIncludes Plug Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1024\" data-end=\"1043\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1041\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1046\" data-end=\"1100\"\u003eOperates on 12 VDC for efficient, low-energy control\u003c\/p\u003e\n\u003cp data-start=\"1103\" data-end=\"1145\"\u003eFast response and consistent performance\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1196\"\u003eDurable construction for extended service life\u003c\/p\u003e\n\u003cp data-start=\"1199\" data-end=\"1249\"\u003eCompact and easy to install in automated systems\u003c\/p\u003e\n\u003cp data-start=\"1252\" data-end=\"1313\"\u003eSuitable for air, inert gas, and fluid control applications\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55973918441797,"sku":null,"price":154.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOX210525720102F3SolenoidValve12DC.jpg?v=1760541202"},{"product_id":"asco-x210525720002f3-solenoid-valve-12dc","title":"ASCO X210525720002F3 Solenoid Valve 12DC","description":"\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Asco X210525720002F3 Solenoid Valve 12DC is a high-performance general service valve designed for reliable operation in demanding industrial environments. Built with precision and durability in mind, this 12V DC solenoid valve delivers consistent control of air, gas, and fluid media, ensuring dependable performance in automation and process applications. As part of Asco’s trusted solenoid valve range, the X210525720002F3 combines robust construction with efficient response times, offering long service life and low maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"30\" data-end=\"498\"\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 0, 0); text-decoration: underline;\"\u003e\u003cstrong\u003eNo Plug Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"967\" data-start=\"948\"\u003e\u003cstrong data-end=\"965\" data-start=\"948\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1027\" data-start=\"970\"\u003e\u003cstrong data-end=\"982\" data-start=\"970\"\u003eVoltage:\u003c\/strong\u003e 12V DC for efficient low-voltage operation\u003c\/p\u003e\n\u003cp data-end=\"1098\" data-start=\"1030\"\u003e\u003cstrong data-end=\"1054\" data-start=\"1030\"\u003eReliable performance\u003c\/strong\u003e across varying pressures and temperatures\u003c\/p\u003e\n\u003cp data-end=\"1178\" data-start=\"1101\"\u003e\u003cstrong data-end=\"1134\" data-start=\"1101\"\u003eCompact, durable construction\u003c\/strong\u003e ideal for space-constrained installations\u003c\/p\u003e\n\u003cp data-end=\"1250\" data-start=\"1181\"\u003e\u003cstrong data-end=\"1203\" data-start=\"1181\"\u003eFast response time\u003c\/strong\u003e for precise control of air, gas, and liquids\u003c\/p\u003e\n\u003cp data-end=\"1320\" data-start=\"1253\"\u003e\u003cstrong data-end=\"1273\" data-start=\"1253\"\u003eDesigned by Asco\u003c\/strong\u003e, a leading name in solenoid valve technology\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"Default Title","offer_id":55973927846213,"sku":null,"price":154.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOX210525720002F3SolenoidValve12DC.jpg?v=1760541282"},{"product_id":"asco-solenoid-valves-scxh210g202bw-2-2-nc15mm-wras-approved-for-water","title":"ASCO Solenoid Valves SCXH210G202BW 2\/2 NC15MM Wras Approved For Water","description":"\u003ch2 data-start=\"26\" data-end=\"405\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003cstrong\u003eIN STOCK - SAME DAY DISPATCH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 data-end=\"405\" data-start=\"26\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"text-decoration: underline; color: rgb(0, 144, 241);\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"498\" data-start=\"30\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe ASCO SCXH210G202BW is a high-quality 2\/2 normally closed (NC) solenoid valve, specifically designed for water applications and certified for potable water use with WRAS approval. With a 15 mm (½\") compression connection, it offers reliable shut-off performance in washroom, plumbing, and general fluid control systems.\u003c\/p\u003e\n\u003cp data-start=\"1350\" data-end=\"1368\"\u003e\u003cstrong data-start=\"1350\" data-end=\"1366\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1371\" data-end=\"1406\"\u003eType: 2-way, normally closed (NC)\u003c\/p\u003e\n\u003cp data-start=\"1409\" data-end=\"1493\"\u003ePort size: 15 mm compression \/ ½″ equivalent \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1496\" data-end=\"1582\"\u003eWRAS-approved EPDM seals for potable water use \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1585\" data-end=\"1687\"\u003ePilot-operated hung diaphragm design (low pressure capability) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1690\" data-end=\"1799\"\u003eSuitable for water, air, inert gases, light oils compatible with EPDM \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1802\" data-end=\"1923\"\u003eCompliant with Pressure Equipment Directive (PED 97\/23\/EC) for group 1 \u0026amp; 2 fluids \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1926\" data-end=\"2038\"\u003eCompact, reliable construction adapted for washroom \/ sanitary systems\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"6VDC","offer_id":55974011306309,"sku":null,"price":154.59,"currency_code":"GBP","in_stock":true},{"title":"12VDC","offer_id":55974011339077,"sku":null,"price":154.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ASCOSolenoidValvesSCXH210G202BW2_2NC15MMWrasApprovedForWater.jpg?v=1760541933"},{"product_id":"valve-actuator-square-drive-shaft-adaptors-10-pieces","title":"Valve Actuator Square Drive Shaft Adaptors (10 Pieces)","description":"\u003cp data-start=\"79\" data-end=\"442\"\u003eThe Valve Actuator Square Drive Shaft Adaptors are designed to provide a perfect connection between actuators and valve drive shafts of varying sizes. Supplied as a set of 10 precision-engineered adaptors, this pack ensures seamless compatibility and smooth torque transmission across multiple valve and actuator combinations.\u003c\/p\u003e\n\u003cp data-start=\"444\" data-end=\"804\"\u003eManufactured from high-strength steel and machined to tight tolerances, these adaptors offer long-lasting durability and accurate alignment for both manual and automated valve setups. Ideal for maintenance teams, OEMs, and valve automation specialists, they eliminate the need for custom machining when pairing components with mismatched shaft sizes.\u003c\/p\u003e\n\u003cp data-start=\"806\" data-end=\"1129\"\u003eEach adaptor in the set is built for square drive shaft systems, ensuring a secure fit that maintains rotational accuracy and minimises backlash. Perfect for use with pneumatic, electric, or hydraulic actuators, these adaptors provide the flexibility and reliability required in demanding industrial environments.\u003c\/p\u003e\n\u003ch2 data-start=\"1131\" data-end=\"1150\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1148\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1153\" data-end=\"1208\"\u003ePack of 10 precision-engineered square drive adaptors\u003c\/p\u003e\n\u003cp data-start=\"1211\" data-end=\"1283\"\u003eEnables compatibility between different actuator and valve drive sizes\u003c\/p\u003e\n\u003cp data-start=\"1286\" data-end=\"1342\"\u003eHigh-strength steel construction for long service life\u003c\/p\u003e\n\u003cp data-start=\"1345\" data-end=\"1400\"\u003eEnsures smooth torque transfer and alignment accuracy\u003c\/p\u003e\n\u003cp data-start=\"1403\" data-end=\"1468\"\u003eSuitable for pneumatic, electric, and hydraulic valve actuators\u003c\/p\u003e\n\u003cp data-start=\"1471\" data-end=\"1536\"\u003eIdeal for workshops, installers, and valve automation engineers\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"14mm x 11mm","offer_id":55992864899397,"sku":null,"price":60.0,"currency_code":"GBP","in_stock":true},{"title":"11mm x 9mm","offer_id":55992864932165,"sku":null,"price":70.0,"currency_code":"GBP","in_stock":true},{"title":"14mm x 9mm","offer_id":55992864964933,"sku":null,"price":90.0,"currency_code":"GBP","in_stock":true},{"title":"17mm x 14mm","offer_id":55992864997701,"sku":null,"price":90.0,"currency_code":"GBP","in_stock":true},{"title":"22mm x 17mm","offer_id":55992865030469,"sku":null,"price":100.0,"currency_code":"GBP","in_stock":true},{"title":"27mm x 22mm","offer_id":55992865063237,"sku":null,"price":120.0,"currency_code":"GBP","in_stock":true},{"title":"11mm x 8mm","offer_id":55992865096005,"sku":null,"price":200.0,"currency_code":"GBP","in_stock":true},{"title":"17mm x 11mm","offer_id":55992865128773,"sku":null,"price":200.0,"currency_code":"GBP","in_stock":true},{"title":"27mm x 14mm","offer_id":55992865161541,"sku":null,"price":200.0,"currency_code":"GBP","in_stock":true},{"title":"22mm x 19mm","offer_id":55992865194309,"sku":null,"price":280.0,"currency_code":"GBP","in_stock":true},{"title":"36mm x 27mm","offer_id":55992865227077,"sku":null,"price":280.0,"currency_code":"GBP","in_stock":true},{"title":"22mm x 11mm","offer_id":55992865259845,"sku":null,"price":500.0,"currency_code":"GBP","in_stock":true},{"title":"27mm x 19mm","offer_id":55992865292613,"sku":null,"price":500.0,"currency_code":"GBP","in_stock":true},{"title":"36mm x 30mm","offer_id":55992865325381,"sku":null,"price":840.0,"currency_code":"GBP","in_stock":true},{"title":"36mm x 22mm","offer_id":55992865358149,"sku":null,"price":900.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/ValveActuatorSquareDriveShaftAdaptors_10Pieces.jpg?v=1760695097"},{"product_id":"hytork-pneumatic-actuator-repair-kits","title":"Hytork Pneumatic Actuator Repair Kits","description":"\u003cp data-end=\"436\" data-start=\"46\"\u003eThe Hytork Pneumatic Actuator Repair Kit XL0026M (Pack of 5) is designed to support reliable maintenance and refurbishment of Hytork pneumatic actuators operating in demanding industrial environments. This kit contains essential replacement sealing components required to restore actuator integrity, helping maintain consistent torque output, air efficiency, and dependable valve operation.\u003c\/p\u003e\n\u003cp data-end=\"801\" data-start=\"438\"\u003eManufactured to suit Hytork XL-series pneumatic actuators, the XL0026M repair kit is ideal for both preventative maintenance programmes and corrective repairs where seal wear, air leakage, or reduced performance has been identified. By replacing worn internal components, this kit helps extend actuator service life while reducing the risk of unexpected downtime.\u003c\/p\u003e\n\u003cp data-end=\"1110\" data-start=\"803\"\u003eSupplying the repair kit in a convenient pack of five makes it well suited for maintenance teams managing multiple actuators or holding critical spares on site. This allows servicing work to be carried out quickly during planned shutdowns or reactive maintenance without delays caused by parts availability.\u003c\/p\u003e","brand":"Valves UK","offers":[{"title":"XL0026M - Pack of 4","offer_id":56822223339845,"sku":null,"price":776.08,"currency_code":"GBP","in_stock":true},{"title":"XL0071M - Pack of 4","offer_id":56822223372613,"sku":null,"price":789.64,"currency_code":"GBP","in_stock":true},{"title":"XL0131M - Pack of 4","offer_id":56822223405381,"sku":null,"price":789.64,"currency_code":"GBP","in_stock":true},{"title":"XL0186M - Pack of 4","offer_id":56822223438149,"sku":null,"price":810.28,"currency_code":"GBP","in_stock":true},{"title":"XL0221M - Pack of 4","offer_id":56822223470917,"sku":null,"price":946.28,"currency_code":"GBP","in_stock":true},{"title":"XL0281M - Pack of 4","offer_id":56822223503685,"sku":null,"price":946.28,"currency_code":"GBP","in_stock":true},{"title":"XL0426M - Pack of 3","offer_id":56822223536453,"sku":null,"price":848.32,"currency_code":"GBP","in_stock":true},{"title":"XL0681M - Pack of 3","offer_id":56822223569221,"sku":null,"price":848.32,"currency_code":"GBP","in_stock":true},{"title":"XL1127M - Pack of 3","offer_id":56822223601989,"sku":null,"price":1012.74,"currency_code":"GBP","in_stock":true},{"title":"XL1372M - Pack of 3","offer_id":56822223634757,"sku":null,"price":1123.91,"currency_code":"GBP","in_stock":true},{"title":"XL2586M - Pack of 3","offer_id":56822223667525,"sku":null,"price":1186.28,"currency_code":"GBP","in_stock":true},{"title":"XL4581M - Pack of 3","offer_id":56822223700293,"sku":null,"price":1254.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/HytorkPneumaticActuatorRepairKits.jpg?v=1767969305"},{"product_id":"pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier","title":"Pepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier from the K-System range. It transfers digital signals from NAMUR sensors or dry contacts located in a hazardous area to relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and power supply circuits.\u003c\/p\u003e\n\u003cp\u003eThe module is powered at 24 V DC via the Pepperl+Fuchs Power Rail or terminals, and its intrinsically safe [Ex ia] inputs are certified under ATEX and IECEx. Line fault detection (LFD), a reversible mode of operation set by DIP switch and suitability for applications up to SIL 2 (SC 3) to IEC\/EN 61508 make it a dependable interface for level, position and limit-switch signals in process plants.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SR2-Ex2.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Isolated Barrier Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier with relay contact outputs\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors (EN 60947-5-6) or dry contacts\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (lead breakage and short circuit)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation, configured by DIP switches\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified [Ex ia] inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SR2-Ex2.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching point \/ hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 … 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 7, 8, 9 and 10, 11, 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, systematic capability SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2080 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1493 X — II 3G Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0034, IECEx TUN 19.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFM (FM19US0207X), UL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHazardous-area limit switch and valve position feedback\u003c\/li\u003e\n\u003cli\u003eLevel switch signals from tanks and vessels in Ex zones\u003c\/li\u003e\n\u003cli\u003eInterfacing NAMUR proximity sensors to PLC and DCS digital inputs\u003c\/li\u003e\n\u003cli\u003eSafety instrumented functions up to SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on a 35 mm DIN rail in the safe area or, where permitted by the Ex ec certificate, in Zone 2. The unit can draw its 24 V DC supply from the Power Rail, which also carries the collective error message. Field wiring connects to terminals 1–6 and the relay outputs to terminals 7–12. Always follow the certificate, instruction manual and control drawings when designing intrinsically safe loops.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier from the K-System range. It transfers digital signals from NAMUR sensors or dry contacts located in a hazardous area to relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and power supply circuits.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SR2-Ex2.W need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/203355_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95426\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SR2-Ex2.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sra-ex4-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SRA-Ex4 – 4-Channel Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SR2-Ex2.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161026687301,"sku":"KFD2-SR2-Ex2.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier-switch-amplifier.jpg?v=1794323780"},{"product_id":"pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB4-12GM50-E2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB4-12GM50-E2-V1 is an M12 inductive proximity sensor for wear-free, non-contact detection of metal targets. It has a rated operating distance of 4 mm, is designed for flush mounting, and switches a PNP normally open output from a 3-wire DC supply.\u003c\/p\u003e\n\u003cp\u003eBuilt for harsh environments, the sensor has high shock resistance, an extended temperature range of -40 … 85 °C, an extended operating voltage range of 6 … 36 V DC and protection up to IP69. A switching frequency of up to 2550 Hz suits fast counting and position tasks, and the M12 connector (V1) allows quick replacement.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB4-12GM50-E2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e4 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003ePNP normally open output, 3-wire DC\u003c\/li\u003e\n\u003cli\u003eExtended operating voltage range 6 … 36 V DC\u003c\/li\u003e\n\u003cli\u003eExtended temperature range -40 … 85 °C\u003c\/li\u003e\n\u003cli\u003eIP65 to IP69 degree of protection\u003c\/li\u003e\n\u003cli\u003eM12 x 1 threaded brass housing, white bronze coated\u003c\/li\u003e\n\u003cli\u003eM12 connector, 3-pin (V1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB4-12GM50-E2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, M12 cylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 3.24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, normally open (NO), 3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e6 … 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 2550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eReverse polarity protected; short-circuit protected (pulsing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicator\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eMultihole LED, yellow (switching state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBrass, white bronze coated; M12 x 1 thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSensing face\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePBT, green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 connector plug, 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eØ 12 mm, length 64.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e29 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP65 \/ IP66 \/ IP67 \/ IP68 \/ IP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA00003AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMachine building and general automation\u003c\/li\u003e\n\u003cli\u003ePosition and presence detection of metal parts\u003c\/li\u003e\n\u003cli\u003eConveyors, packaging and handling equipment\u003c\/li\u003e\n\u003cli\u003eOutdoor, wash-down and harsh-environment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount with the M12 nuts supplied (tightening torque ≤ 10 Nm). Being a flush type, the sensing face can sit level with surrounding metal. Connect via an M12 3-pin cable socket: brown (+), blue (–), black (output).\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB4-12GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB4-12GM50-E2-V1 is an M12 inductive proximity sensor for wear-free, non-contact detection of metal targets. It has a rated operating distance of 4 mm, is designed for flush mounting, and switches a PNP normally open output from a 3-wire DC supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB4-12GM50-E2-V1 need?\u003c\/h3\u003e\u003cp\u003e6 … 36 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB4-12GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/326161-0001_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB4-12GM50-E2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95524\" target=\"_blank\" rel=\"noopener\"\u003eNBB4-12GM50-E2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm30-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM30-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn4-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN4-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB4-12GM50-E2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071284549,"sku":"NBB4-12GM50-E2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor.jpg?v=1794323885"},{"product_id":"pepperl-fuchs-uc2000-30gm-iur2-v15-ultrasonic-sensor","title":"Pepperl+Fuchs UC2000-30GM-IUR2-V15 – Ultrasonic Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs UC2000-30GM-IUR2-V15 is an M30 ultrasonic sensor for non-contact distance measurement over a sensing range of 80 … 2000 mm. Ultrasonic detection is largely unaffected by target colour or transparency, making it suitable for liquids, bulk materials and glass as well as solid objects.\u003c\/p\u003e\n\u003cp\u003eThe sensor provides both a 4 … 20 mA current output and a 0 … 10 V voltage output, with temperature compensation and adjustable acoustic power and sensitivity. Evaluation limits are set with the teach-in connector or via the ULTRA 3000 service software over the RS 232 interface, and synchronisation inputs allow several sensors to operate close together.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e UC2000-30GM-IUR2-V15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Ultrasonic Sensor\u003c\/li\u003e\n\u003cli\u003eSensing range 80 … 2000 mm\u003c\/li\u003e\n\u003cli\u003eAnalogue current (4 … 20 mA) and voltage (0 … 10 V) outputs\u003c\/li\u003e\n\u003cli\u003eTemperature compensation\u003c\/li\u003e\n\u003cli\u003eAdjustable acoustic power and sensitivity\u003c\/li\u003e\n\u003cli\u003eParameterisation via ULTRA 3000 software (RS 232)\u003c\/li\u003e\n\u003cli\u003eSynchronisation for multiple sensors\u003c\/li\u003e\n\u003cli\u003eM30 stainless steel housing, M12 5-pin connector (V15)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUC2000-30GM-IUR2-V15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUltrasonic distance sensor, M30 cylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSensing range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e80 … 2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAdjustment range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e120 … 2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDead band\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eTransducer frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 180 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e10 … 30 V DC, ripple 10 %SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 900 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 × current 4 … 20 mA; 1 × voltage 0 … 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eEvaluation range\/4000, ≥ 0.35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRepeat accuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 0.1 % of full-scale value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInterface\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRS 232, 9600 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSynchronisation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCommon mode max. 30 Hz; multiplex (≤ 5 sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eStainless steel 1.4305 \/ AISI 303, PBT plastic parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 x 1 connector, 5-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eØ 30 mm, length 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed, General Purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLevel measurement in tanks, silos and hoppers\u003c\/li\u003e\n\u003cli\u003eDistance and height measurement\u003c\/li\u003e\n\u003cli\u003eRoll diameter and loop control\u003c\/li\u003e\n\u003cli\u003eDetection of transparent or irregular objects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount with M30 nuts with a clear line of sight to the target and no obstructions inside the sound cone. Respect the 80 mm dead band. Connect via an M12 5-pin cable socket; use synchronisation wiring when several sensors are mounted close together.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs UC2000-30GM-IUR2-V15?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs UC2000-30GM-IUR2-V15 is an M30 ultrasonic sensor for non-contact distance measurement over a sensing range of 80 … 2000 mm. Ultrasonic detection is largely unaffected by target colour or transparency, making it suitable for liquids, bulk materials and glass as well as solid objects.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the UC2000-30GM-IUR2-V15 need?\u003c\/h3\u003e\u003cp\u003e10 … 30 V DC, ripple 10 %SS.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the UC2000-30GM-IUR2-V15?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/104093_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs UC2000-30GM-IUR2-V15 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/4221\" target=\"_blank\" rel=\"noopener\"\u003eUC2000-30GM-IUR2-V15 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-obt150-r101-2ep1-io-v31-triangulation-sensor\"\u003ePepperl+Fuchs OBT150-R101-2EP1-IO-V31 – Triangulation Sensor with Background Suppression\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs UC2000-30GM-IUR2-V15. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071448389,"sku":"UC2000-30GM-IUR2-V15","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-uc2000-30gm-iur2-v15-ultrasonic-sensor.jpg?v=1794323886"},{"product_id":"pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier","title":"Pepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts a NAMUR sensor or dry contact on its intrinsically safe input and switches a relay contact output, keeping input, output and supply circuits galvanically isolated with reinforced insulation.\u003c\/p\u003e\n\u003cp\u003ePart of the K-System, the module runs from 24 V DC via the Power Rail or terminals. Line fault detection, a reversible mode of operation selected by DIP switch and suitability up to SIL 2 (SC 3) to IEC\/EN 61508 make it well suited to single-point switching duties such as limit switches, level switches and valve position feedback.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SR2-Ex1.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier with relay contact output\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation via DIP switch\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified [Ex ia] input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SR2-Ex1.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 0.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1+, 2+, 3-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching point \/ hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 … 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 × relay (terminals 7, 8, 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2080 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1493 X — II 3G Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0034, IECEx TUN 19.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFM (FM19US0207X), UL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle limit switch or proximity sensor signals from Ex zones\u003c\/li\u003e\n\u003cli\u003eValve open\/closed position indication\u003c\/li\u003e\n\u003cli\u003eLevel switch alarms to PLC and DCS inputs\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC supplied from the Power Rail or terminals 14+\/15-. Connect the field device to terminals 1+, 2+, 3- and the relay output to terminals 7, 8, 9. Configure mode of operation and line fault detection with the front DIP switches. Observe the ATEX\/IECEx certificate and instruction manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts a NAMUR sensor or dry contact on its intrinsically safe input and switches a relay contact output, keeping input, output and supply circuits galvanically isolated with reinforced insulation.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SR2-Ex1.W need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70101737_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95424\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SR2-Ex1.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SR2-Ex1.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071513925,"sku":"KFD2-SR2-Ex1.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier.jpg?v=1794323888"},{"product_id":"pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters (and accepts 2-wire SMART current sources) in the hazardous area and repeats the 0\/4 … 20 mA signal to the safe area for PLC, DCS or indicator inputs.\u003c\/p\u003e\n\u003cp\u003eDigital HART communication is transferred bi-directionally, and terminals with test points simplify commissioning and loop checks. The module runs from 24 V DC via the Power Rail, its input is certified [Ex ia] under ATEX and IECEx, and it is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC4-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA output\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC4-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA (terminals 1+, 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 800 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHART bandwidth\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 7.5 kHz (-3 dB), field to control side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 99 ATEX 7060 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 04.0016X, IECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePressure, level and flow transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART-enabled instrument loops\u003c\/li\u003e\n\u003cli\u003eAnalogue input marshalling for PLC\/DCS\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Connect 2-wire transmitters to terminals 1+\/3, 3-wire transmitters to 1+\/2-\/3, or current sources to 5-\/6+. The 0\/4–20 mA output is on terminals 7-\/8+. Check loop parameters (Uo 25.4 V, Io 86.8 mA, Po 551 mW for terminals 1+\/3-) against the field device certificate.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC4-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters (and accepts 2-wire SMART current sources) in the hazardous area and repeats the 0\/4 … 20 mA signal to the safe area for PLC, DCS or indicator inputs.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC4-Ex1 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC4-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/283672_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/75019\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC4-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC4-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071546693,"sku":"KFD2-STC4-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply.jpg?v=1794323890"},{"product_id":"pepperl-fuchs-kcd2-sr-ex2-isolated-barrier","title":"Pepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KCD2-SR-Ex2 is a 2-channel isolated barrier switch amplifier in the space-saving 12.5 mm K-System housing. It transfers switching signals from NAMUR sensors or dry contacts in the hazardous area to two relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003cp\u003ePowered at 24 V DC via the Power Rail or terminals, the module provides line fault detection on each input and is suitable for applications up to SIL 2 (SC 3) to IEC\/EN 61508. Its narrow width allows high-density installation in marshalling and control cabinets, and its ATEX\/IECEx certification includes mounting in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-SR-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Isolated Barrier Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier in a 12.5 mm wide housing\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified, Zone 2 mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKCD2-SR-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 46 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 900 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I ≥ 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 5, 6 and 7, 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 30 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e12.5 x 119 x 114 mm (W x H x D), housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBASEEFA 06 ATEX 0092 X — II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 06.0025 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh-density digital input marshalling\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor and limit switch interfacing\u003c\/li\u003e\n\u003cli\u003eValve position feedback in Ex areas\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on a 35 mm DIN rail; supply 24 V DC via the Power Rail or terminals 9+\/10-. Field circuits connect to terminals 1–4 and the relay outputs to terminals 5–8. Functions are set with DIP switches. The device may be installed in Zone 2 under the Ex ec certification — follow the certificate and manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KCD2-SR-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KCD2-SR-Ex2 is a 2-channel isolated barrier switch amplifier in the space-saving 12.5 mm K-System housing. It transfers switching signals from NAMUR sensors or dry contacts in the hazardous area to two relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KCD2-SR-Ex2 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KCD2-SR-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70112153_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KCD2-SR-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/99636\" target=\"_blank\" rel=\"noopener\"\u003eKCD2-SR-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-stc-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KCD2-SR-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071579461,"sku":"KCD2-SR-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier-switch-amplifier.jpg?v=1794323892"},{"product_id":"pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier-115v-ac","title":"Pepperl+Fuchs KFA5-SR2-Ex2.W – Switch Amplifier (115 V AC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier designed for installations with a 115 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, maintaining reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003cp\u003eLine fault detection identifies lead breakage and short circuits on the field wiring, the mode of operation is reversible via DIP switches, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511. It is a practical choice where control panels are AC powered rather than fed from a 24 V DC Power Rail.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA5-SR2-Ex2.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier (115 V AC)\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e115 V AC supply (103.5 … 126 V AC, 45 … 65 Hz)\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFA5-SR2-Ex2.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 7, 8, 9 and 10, 11, 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 126.5 V AC \/ 4 A; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2081 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC-powered control panels interfacing Ex-area switches\u003c\/li\u003e\n\u003cli\u003eLimit switch and valve position signals\u003c\/li\u003e\n\u003cli\u003eLevel switch alarms\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting in the safe area with 115 V AC supply on terminals 14 and 15 (this model does not use the Power Rail for supply). Field devices connect to terminals 1–6 and relay outputs to terminals 7–12. Configure via DIP switches and follow the certificate and manual for intrinsically safe wiring.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFA5-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier designed for installations with a 115 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, maintaining reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFA5-SR2-Ex2.W need?\u003c\/h3\u003e\u003cp\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFA5-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/103370_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFA5-SR2-Ex2.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/3134\" target=\"_blank\" rel=\"noopener\"\u003eKFA5-SR2-Ex2.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa6-sr2-ex2-w-switch-amplifier-230v-ac\"\u003ePepperl+Fuchs KFA6-SR2-Ex2.W – Switch Amplifier (230 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFA5-SR2-Ex2.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161072824645,"sku":"KFA5-SR2-Ex2.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier.jpg?v=1794323894"},{"product_id":"pepperl-fuchs-nbb20-u4-uu-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB20-U4-UU – Inductive Proximity Sensor (AC\/DC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB20-U4-UU is a 40 x 40 mm inductive proximity sensor with a 20 mm rated operating distance for flush mounting and a universal 2-wire AC\/DC output. It operates from 20 … 253 V AC or 20 … 275 V DC and switches loads up to 500 mA directly.\u003c\/p\u003e\n\u003cp\u003eThe switching function is selectable between normally open and normally closed, and the sensor head is bidirectional and rotatable. A metal base with ground connection, terminal compartment wiring and IP67 protection make it a rugged replacement for mechanical limit switches on heavy machinery.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB20-U4-UU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor (AC\/DC)\u003c\/li\u003e\n\u003cli\u003e20 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003eUniversal 2-wire AC\/DC output\u003c\/li\u003e\n\u003cli\u003eNO\/NC selectable\u003c\/li\u003e\n\u003cli\u003eOperating current up to 500 mA\u003c\/li\u003e\n\u003cli\u003eBidirectional, rotatable sensor head\u003c\/li\u003e\n\u003cli\u003eMetal base with ground connection\u003c\/li\u003e\n\u003cli\u003eTerminal compartment wiring, IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB20-U4-UU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, 40 x 40 mm limit-switch style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 16.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-wire AC\/DC, NO\/NC selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e24 … 250 V DC \/ 24 … 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 275 V DC \/ 20 … 253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAC 0 … 30 Hz; DC 0 … 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e5 … 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOff-state current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicators\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eLED green (power), LED yellow (switching); flashes on overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePA 6.6 \/ metal base with ground connection (protection class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTerminal compartment, conductors up to 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 40 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReplacing mechanical limit switches\u003c\/li\u003e\n\u003cli\u003eCranes, hoists and heavy machinery\u003c\/li\u003e\n\u003cli\u003eAC or DC control circuits\u003c\/li\u003e\n\u003cli\u003eConveyors and material handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on the metal base and connect the protective earth. Wire in the terminal compartment (max. two conductors of the same cross-section per terminal). Select NO\/NC as described in the manual. Observe minimum operating current 5 mA.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB20-U4-UU?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB20-U4-UU is a 40 x 40 mm inductive proximity sensor with a 20 mm rated operating distance for flush mounting and a universal 2-wire AC\/DC output. It operates from 20 … 253 V AC or 20 … 275 V DC and switches loads up to 500 mA directly.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB20-U4-UU need?\u003c\/h3\u003e\u003cp\u003e20 … 275 V DC \/ 20 … 253 V AC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB20-U4-UU?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/248043_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB20-U4-UU datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/60385\" target=\"_blank\" rel=\"noopener\"\u003eNBB20-U4-UU on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn40-u4-uu-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN40-U4-UU – Inductive Proximity Sensor (AC\/DC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb5-18gm60-ws-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB5-18GM60-WS – Inductive Proximity Sensor (2-Wire AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB20-U4-UU. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161073348933,"sku":"NBB20-U4-UU","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb20-u4-uu-inductive-proximity-sensor.jpg?v=1794323896"},{"product_id":"pepperl-fuchs-nbb8-18gm50-e2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB8-18GM50-E2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB8-18GM50-E2-V1 is an M18 inductive proximity sensor with an 8 mm rated operating distance for flush mounting. It detects metal targets without contact and switches a PNP normally open output from a 3-wire DC supply.\u003c\/p\u003e\n\u003cp\u003eBuilt for harsh environments, it offers high shock resistance, an extended temperature range of -40 … 85 °C, an extended operating voltage range of 6 … 36 V DC, IP65 to IP69 protection and switching frequencies up to 1350 Hz. Connection is via an M12 connector (V1).\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB8-18GM50-E2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e8 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003ePNP normally open output, 3-wire DC\u003c\/li\u003e\n\u003cli\u003eExtended operating voltage range 6 … 36 V DC\u003c\/li\u003e\n\u003cli\u003eExtended temperature range -40 … 85 °C\u003c\/li\u003e\n\u003cli\u003eIP65 to IP69 degree of protection\u003c\/li\u003e\n\u003cli\u003eM18 threaded brass housing, white bronze coated\u003c\/li\u003e\n\u003cli\u003eM12 connector, 3-pin (V1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB8-18GM50-E2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, M18 cylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 6.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, normally open (NO), 3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e6 … 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 1350 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eReverse polarity protected; short-circuit protected (pulsing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicator\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eMultihole LED, yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBrass, white bronze coated; mounting with M18 nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSensing face\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePBT, green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 connector plug, 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eØ 18 mm, length 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e61 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP65 \/ IP66 \/ IP67 \/ IP68 \/ IP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA00003AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMachine building and general automation\u003c\/li\u003e\n\u003cli\u003ePosition and presence detection of metal parts\u003c\/li\u003e\n\u003cli\u003eConveyors, packaging and handling equipment\u003c\/li\u003e\n\u003cli\u003eOutdoor, wash-down and harsh-environment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount with M18 nuts. Flush design allows the sensing face to be embedded in metal. Connect via an M12 3-pin cable socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB8-18GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB8-18GM50-E2-V1 is an M18 inductive proximity sensor with an 8 mm rated operating distance for flush mounting. It detects metal targets without contact and switches a PNP normally open output from a 3-wire DC supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB8-18GM50-E2-V1 need?\u003c\/h3\u003e\u003cp\u003e6 … 36 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB8-18GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/326161-0087_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB8-18GM50-E2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95774\" target=\"_blank\" rel=\"noopener\"\u003eNBB8-18GM50-E2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb5-18gm60-ws-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB5-18GM60-WS – Inductive Proximity Sensor (2-Wire AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB8-18GM50-E2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161075020101,"sku":"NBB8-18GM50-E2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb8-18gm50-e2-v1-inductive-proximity-sensor.jpg?v=1794323898"},{"product_id":"pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003cp\u003eHART communication is passed bi-directionally, and terminals with test points support commissioning and maintenance. The unit is supplied at 24 V DC via the Power Rail, is ATEX and IECEx certified for [Ex ia] inputs and is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC4-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 2-Channel SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA output per channel\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC4-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA from 2-wire transmitters (terminals 1+, 3-; 4+, 6-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA per channel (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 550 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 99 ATEX 7025 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 04.0015X, IECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo analogue transmitter loops per module\u003c\/li\u003e\n\u003cli\u003ePressure, level and temperature transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART asset management access\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail. Transmitters connect to terminals 1+\/3- (channel I) and 4+\/6- (channel II); outputs are on 7-\/8+ and 10-\/11+. Observe the certificate and safety manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC4-Ex2 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/283699_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/75015\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC4-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC4-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161076232517,"sku":"KFD2-STC4-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc4-ex2-2-channel-smart-transmitter-power-supply.jpg?v=1794323901"},{"product_id":"pepperl-fuchs-hm-pf-usb-010031-viator-usb-hart-interface","title":"Pepperl+Fuchs HM-PF-USB-010031 – Viator USB HART Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs HM-PF-USB-010031 is a Viator USB HART interface (modem) for connecting a Windows PC to HART field devices. It is used to commission, configure, calibrate and diagnose HART-enabled transmitters and valve positioners from configuration software on a laptop.\u003c\/p\u003e\n\u003cp\u003eThe modem is HART compliant for communication with any HART field device, draws its power from the USB port so no external supply is needed, and is housed in a compact, rugged polycarbonate case. An integrated cable ends in two polarity-insensitive test clips for quick connection to the 4 … 20 mA loop.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e HM-PF-USB-010031\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Viator USB HART Interface\u003c\/li\u003e\n\u003cli\u003eHART compliant — communicates with any HART field device\u003c\/li\u003e\n\u003cli\u003ePowered from the USB port, no external supply\u003c\/li\u003e\n\u003cli\u003eCompatible with Windows 7, 10 and 11\u003c\/li\u003e\n\u003cli\u003eUSB 1.1 compliant\u003c\/li\u003e\n\u003cli\u003ePolarity-insensitive test clips\u003c\/li\u003e\n\u003cli\u003eRugged polycarbonate housing\u003c\/li\u003e\n\u003cli\u003e1500 V DC isolation between loop and USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eHM-PF-USB-010031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUSB HART modem \/ interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInterface\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUSB (type A connector), USB 1.1 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUSB powered, approx. 11 mA at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.5 ± 0.1 Vpp trapezoidal wave at 1200\/2200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1500 V DC, output\/interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating system\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eWindows 7, 10 and 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e75 x 33 x 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.8 m 2-strand cable with 2 test clips; 15.2 cm cable to USB type A connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommissioning and configuring HART transmitters\u003c\/li\u003e\n\u003cli\u003eCalibration and diagnostics in the field or workshop\u003c\/li\u003e\n\u003cli\u003eValve positioner set-up via HART\u003c\/li\u003e\n\u003cli\u003eAsset management with PC-based DTM\/FDT software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003ePlug into a PC USB port and install the supplied driver. Clip the test leads across the loop resistor or the device HART terminals (polarity insensitive). HART communication requires a suitable loop resistance (commonly 250 Ω). Refer to the manufacturer's instruction manual for connection details and any restrictions on use in or near hazardous areas.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs HM-PF-USB-010031?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs HM-PF-USB-010031 is a Viator USB HART interface (modem) for connecting a Windows PC to HART field devices. It is used to commission, configure, calibrate and diagnose HART-enabled transmitters and valve positioners from configuration software on a laptop.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the HM-PF-USB-010031 need?\u003c\/h3\u003e\u003cp\u003eUSB powered, approx. 11 mA at 5 V.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the HM-PF-USB-010031?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70173956_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs HM-PF-USB-010031 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/135933\" target=\"_blank\" rel=\"noopener\"\u003eHM-PF-USB-010031 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-stc-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs HM-PF-USB-010031. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161080066373,"sku":"HM-PF-USB-010031","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-hm-pf-usb-010031-viator-usb-hart-interface.jpg?v=1794323902"},{"product_id":"pepperl-fuchs-nbb2-12gm50-e2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB2-12GM50-E2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB2-12GM50-E2-V1 is an M12 inductive proximity sensor with a 2 mm rated operating distance for flush installation. It detects metal targets without contact and switches a PNP normally open output on a 3-wire DC circuit.\u003c\/p\u003e\n\u003cp\u003eDesigned for use in harsh environments, it offers high shock resistance, an extended temperature range of -40 … 85 °C, an extended operating voltage range of 6 … 36 V DC, IP65 to IP69 protection and a very high switching frequency of up to 3500 Hz. Connection is by M12 connector (V1).\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB2-12GM50-E2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e2 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003ePNP normally open output, 3-wire DC\u003c\/li\u003e\n\u003cli\u003eExtended operating voltage range 6 … 36 V DC\u003c\/li\u003e\n\u003cli\u003eExtended temperature range -40 … 85 °C\u003c\/li\u003e\n\u003cli\u003eIP65 to IP69 degree of protection\u003c\/li\u003e\n\u003cli\u003eM12 x 1 threaded brass housing, white bronze coated\u003c\/li\u003e\n\u003cli\u003eM12 connector, 3-pin (V1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB2-12GM50-E2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, M12 cylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 1.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, normally open (NO), 3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e6 … 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 3500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eReverse polarity protected; short-circuit protected (pulsing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicator\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eMultihole LED, yellow (switching state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBrass, white bronze coated; M12 x 1 thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSensing face\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePBT, green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 connector plug, 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eØ 12 mm, length 64.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e29 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP65 \/ IP66 \/ IP67 \/ IP68 \/ IP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA00003AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMachine building and general automation\u003c\/li\u003e\n\u003cli\u003ePosition and presence detection of metal parts\u003c\/li\u003e\n\u003cli\u003eConveyors, packaging and handling equipment\u003c\/li\u003e\n\u003cli\u003eOutdoor, wash-down and harsh-environment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount with M12 nuts (≤ 10 Nm). Flush design allows the sensing face to be embedded in metal. Connect via an M12 3-pin cable socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB2-12GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB2-12GM50-E2-V1 is an M12 inductive proximity sensor with a 2 mm rated operating distance for flush installation. It detects metal targets without contact and switches a PNP normally open output on a 3-wire DC circuit.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB2-12GM50-E2-V1 need?\u003c\/h3\u003e\u003cp\u003e6 … 36 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB2-12GM50-E2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/326161-0027_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB2-12GM50-E2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/98939\" target=\"_blank\" rel=\"noopener\"\u003eNBB2-12GM50-E2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm30-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM30-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB2-12GM50-E2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161082458437,"sku":"NBB2-12GM50-E2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb2-12gm50-e2-v1-inductive-proximity-sensor.jpg?v=1794323905"},{"product_id":"pepperl-fuchs-nbb4-12gm30-e2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB4-12GM30-E2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB4-12GM30-E2-V1 is a short-body M12 inductive proximity sensor with a 4 mm rated operating distance for flush mounting. At 44.5 mm long it suits installations where space behind the mounting point is limited, while still switching a PNP normally open output on 3-wire DC.\u003c\/p\u003e\n\u003cp\u003eThe sensor is intended for harsh environments, with high shock resistance, -40 … 85 °C operating temperature, a 6 … 36 V DC operating voltage range, IP65 to IP69 protection and switching frequencies up to 2550 Hz. It connects via an M12 connector (V1).\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB4-12GM30-E2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e4 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003ePNP normally open output, 3-wire DC\u003c\/li\u003e\n\u003cli\u003eExtended operating voltage range 6 … 36 V DC\u003c\/li\u003e\n\u003cli\u003eExtended temperature range -40 … 85 °C\u003c\/li\u003e\n\u003cli\u003eIP65 to IP69 degree of protection\u003c\/li\u003e\n\u003cli\u003eM12 x 1 threaded brass housing, white bronze coated\u003c\/li\u003e\n\u003cli\u003eM12 connector, 3-pin (V1)\u003c\/li\u003e\n\u003cli\u003eShort 44.5 mm housing for tight spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB4-12GM30-E2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, M12 cylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 3.24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, normally open (NO), 3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e6 … 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 2550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eReverse polarity protected; short-circuit protected (pulsing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicator\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eMultihole LED, yellow (switching state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBrass, white bronze coated; M12 x 1 thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSensing face\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePBT, green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 connector plug, 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eØ 12 mm, length 44.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e23 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP65 \/ IP66 \/ IP67 \/ IP68 \/ IP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA00003AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMachine building and general automation\u003c\/li\u003e\n\u003cli\u003ePosition and presence detection of metal parts\u003c\/li\u003e\n\u003cli\u003eConveyors, packaging and handling equipment\u003c\/li\u003e\n\u003cli\u003eOutdoor, wash-down and harsh-environment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount with M12 nuts (≤ 10 Nm). Flush design. Connect via an M12 3-pin cable socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB4-12GM30-E2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB4-12GM30-E2-V1 is a short-body M12 inductive proximity sensor with a 4 mm rated operating distance for flush mounting. At 44.5 mm long it suits installations where space behind the mounting point is limited, while still switching a PNP normally open output on 3-wire DC.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB4-12GM30-E2-V1 need?\u003c\/h3\u003e\u003cp\u003e6 … 36 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB4-12GM30-E2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/326161-0014_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB4-12GM30-E2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/100452\" target=\"_blank\" rel=\"noopener\"\u003eNBB4-12GM30-E2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb4-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB4-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb2-12gm50-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB2-12GM50-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB4-12GM30-E2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161083867461,"sku":"NBB4-12GM30-E2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb4-12gm30-e2-v1-inductive-proximity-sensor.jpg?v=1794323906"},{"product_id":"pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac","title":"Pepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for 115 V AC powered installations. It reads a NAMUR sensor or dry contact located in a hazardous area and switches a relay contact output in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003cp\u003eThe unit provides line fault detection, a reversible mode of operation selected by DIP switch, and suitability for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511. Its intrinsically safe input is certified under ATEX and IECEx for Ex ia applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA5-SR2-Ex1.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier (115 V AC)\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e115 V AC supply (103.5 … 126 V AC)\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003eRelay contact output\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFA5-SR2-Ex1.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1+, 2+, 3-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 × relay (terminals 7, 8, 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 126.5 V AC \/ 4 A; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2081 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle-point switching signals from Ex zones in AC-powered panels\u003c\/li\u003e\n\u003cli\u003eValve position feedback\u003c\/li\u003e\n\u003cli\u003eLevel and limit switch alarms\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 115 V AC supply on terminals 14\/15. Connect the field device to terminals 1+, 2+, 3- and the relay output to terminals 7, 8, 9. Configure with the front DIP switches and follow the certificate and instruction manual for intrinsically safe loops.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFA5-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for 115 V AC powered installations. It reads a NAMUR sensor or dry contact located in a hazardous area and switches a relay contact output in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFA5-SR2-Ex1.W need?\u003c\/h3\u003e\u003cp\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFA5-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/103371_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/3132\" target=\"_blank\" rel=\"noopener\"\u003eKFA5-SR2-Ex1.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex2.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFA5-SR2-Ex1.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161083998533,"sku":"KFA5-SR2-Ex1.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier.jpg?v=1794323909"},{"product_id":"pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-CRG2-Ex1.D is a 1-channel isolated barrier transmitter power supply with trip values. It powers 2-wire and 3-wire transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 0\/4 … 20 mA analogue output together with two relay contact outputs for high\/low alarms.\u003c\/p\u003e\n\u003cp\u003eAlarm set points, energised\/de-energised delays (0 … 250 s) and a linearisation function of up to 20 points are programmed via the front keypad and display or with PACTware. Line fault detection monitors the input circuit, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-CRG2-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Transmitter Power Supply with Trip Values\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eInput for 2-wire and 3-wire transmitters and 2-wire current sources\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA analogue output\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs with programmable high\/low alarms\u003c\/li\u003e\n\u003cli\u003eAdjustable energised\/de-energised delay\u003c\/li\u003e\n\u003cli\u003eLinearisation function (max. 20 points)\u003c\/li\u003e\n\u003cli\u003eLine fault detection; up to SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-CRG2-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel transmitter power supply with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 15 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I \u0026lt; 0.2 mA; short circuit I \u0026gt; 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 253 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDelay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 250 s, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 01 ATEX 1701 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1885 X — II 3G Ex nA nC IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 09.0007, IECEx TSA 18.0007X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E223772)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLevel and pressure transmitters with local high\/low alarm relays\u003c\/li\u003e\n\u003cli\u003eAnalogue signal isolation with limit monitoring\u003c\/li\u003e\n\u003cli\u003ePump and process protection trips\u003c\/li\u003e\n\u003cli\u003eSIL 2 limit value monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide) with 24 V DC from the Power Rail or terminals 23+\/24-. Transmitter connects to terminals 1, 2, 3; relays to 10–12 and 16–18; analogue output to 8+\/7-. Configure via the keypad or PACTware using the programming socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-CRG2-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-CRG2-Ex1.D is a 1-channel isolated barrier transmitter power supply with trip values. It powers 2-wire and 3-wire transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 0\/4 … 20 mA analogue output together with two relay contact outputs for high\/low alarms.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-CRG2-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-CRG2-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/255620_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/58378\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-CRG2-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter\"\u003ePepperl+Fuchs KFD2-UFC-Ex1.D – Universal Frequency Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter\"\u003ePepperl+Fuchs KFD2-GUT-Ex1.D – Temperature Converter with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-CRG2-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161085276485,"sku":"KFD2-CRG2-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply-with-trip-values.jpg?v=1794323911"},{"product_id":"pepperl-fuchs-nbn40-u4-uu-inductive-proximity-sensor","title":"Pepperl+Fuchs NBN40-U4-UU – Inductive Proximity Sensor (AC\/DC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBN40-U4-UU is a long-range 40 x 40 mm inductive proximity sensor with a 40 mm rated operating distance for non-flush mounting and a universal 2-wire AC\/DC output, operating from 20 … 253 V AC or 20 … 275 V DC.\u003c\/p\u003e\n\u003cp\u003eIts switching function is selectable between NO and NC, the sensor head is bidirectional and rotatable, and the metal base with ground connection gives a robust, limit-switch style installation. Terminal compartment wiring and IP67 protection suit heavy-duty industrial applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBN40-U4-UU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor (AC\/DC)\u003c\/li\u003e\n\u003cli\u003e40 mm rated operating distance, non-flush mounting\u003c\/li\u003e\n\u003cli\u003eUniversal 2-wire AC\/DC output\u003c\/li\u003e\n\u003cli\u003eNO\/NC selectable\u003c\/li\u003e\n\u003cli\u003eOperating current up to 500 mA\u003c\/li\u003e\n\u003cli\u003eBidirectional, rotatable sensor head\u003c\/li\u003e\n\u003cli\u003eMetal base with ground connection\u003c\/li\u003e\n\u003cli\u003eTerminal compartment wiring, IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBN40-U4-UU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, 40 x 40 mm limit-switch style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 32.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNon-flush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-wire AC\/DC, NO\/NC selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e24 … 250 V DC \/ 24 … 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 275 V DC \/ 20 … 253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAC 0 … 30 Hz; DC 0 … 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e5 … 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOff-state current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicators\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eLED green (power), LED yellow (switching); flashes on overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePA 6.6 \/ metal base with ground connection (protection class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTerminal compartment, conductors up to 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 40 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLong-range detection on cranes and heavy machinery\u003c\/li\u003e\n\u003cli\u003eReplacing mechanical limit switches\u003c\/li\u003e\n\u003cli\u003eAC or DC control circuits\u003c\/li\u003e\n\u003cli\u003eMaterial handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on the metal base and connect the protective earth. Non-flush: keep the free zone around the sensing face clear of metal. Wire in the terminal compartment; select NO\/NC as described in the manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBN40-U4-UU?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBN40-U4-UU is a long-range 40 x 40 mm inductive proximity sensor with a 40 mm rated operating distance for non-flush mounting and a universal 2-wire AC\/DC output, operating from 20 … 253 V AC or 20 … 275 V DC.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBN40-U4-UU need?\u003c\/h3\u003e\u003cp\u003e20 … 275 V DC \/ 20 … 253 V AC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBN40-U4-UU?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/248047_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBN40-U4-UU datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/60381\" target=\"_blank\" rel=\"noopener\"\u003eNBN40-U4-UU on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb20-u4-uu-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB20-U4-UU – Inductive Proximity Sensor (AC\/DC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn40-l2-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN40-L2-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBN40-U4-UU. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161086488901,"sku":"NBN40-U4-UU","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbn40-u4-uu-inductive-proximity-sensor.jpg?v=1794323913"},{"product_id":"pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, and accepts 2-wire SMART current sources, in the hazardous area, repeating each 4 … 20 mA signal to the safe area as a current sink or current source output.\u003c\/p\u003e\n\u003cp\u003eHART communication is transferred bi-directionally and terminals with test points simplify loop checks. Supplied at 24 V DC via the Power Rail, the module is ATEX and IECEx certified, suitable for applications up to SIL 2 (SC 3) to IEC\/EN 61508, and can also be installed in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC5-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 2-Channel SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA output, current sink or source\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC5-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 2.6 W at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA; ≥ 20 V at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA, sink or source (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C (up to 70 °C with mounting conditions per manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCML 17 ATEX 2031X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; CML 17 ATEX 3030X — II 3G Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx CML 17.0016X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo analogue transmitter loops per module\u003c\/li\u003e\n\u003cli\u003eFlow, pressure and level measurement in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART asset management\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail. Sink or source output is selected by the output terminal arrangement (see manual). Observe the certificate, loop parameters and safety manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC5-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, and accepts 2-wire SMART current sources, in the hazardous area, repeating each 4 … 20 mA signal to the safe area as a current sink or current source output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC5-Ex2 need?\u003c\/h3\u003e\u003cp\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC5-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/203645_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/63975\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC5-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC5-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161088749893,"sku":"KFD2-STC5-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc5-ex2-2-channel-smart-transmitter-power-supply.jpg?v=1794323916"},{"product_id":"pepperl-fuchs-kfd2-ut2-ex1-temperature-converter","title":"Pepperl+Fuchs KFD2-UT2-Ex1 – Universal Temperature Converter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-UT2-Ex1 is a 1-channel isolated barrier universal temperature converter. It accepts thermocouple, RTD, potentiometer or millivolt inputs from the hazardous area and converts them into a 0\/4 … 20 mA current output for PLC, DCS or recorder inputs.\u003c\/p\u003e\n\u003cp\u003eThe output can operate in sink or source mode, and line fault and sensor burnout detection drive a NAMUR NE43 fault signal. The module is configured with PACTware, supplied at 24 V DC via the Power Rail or terminals, and suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-UT2-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Universal Temperature Converter\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eThermocouple, RTD, potentiometer or voltage input\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output, sink or source\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (internal or external)\u003c\/li\u003e\n\u003cli\u003eLine fault and sensor burnout detection\u003c\/li\u003e\n\u003cli\u003eConfigured with PACTware\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-UT2-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel temperature converter \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 0.98 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRTD inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePt10–Pt1000 (EN 60751), Cu and other types; 2-, 3- or 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eThermocouple inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTypes B, E, J, K, N, R, S, T (IEC 584-1) and L (DIN 43710)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePotentiometer 0 … 20 kΩ; voltage -100 … 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA; source load 0 … 550 Ω or sink mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFault signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDownscale 0 or 2 mA, upscale 21.5 mA (NAMUR NE43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePACTware via programming socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 130 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCESI 04 ATEX 143 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1797 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 07.0003, IECEx CML 16.0126X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTemperature measurement with RTDs or thermocouples in Ex zones\u003c\/li\u003e\n\u003cli\u003eReactor, vessel and pipeline temperature loops\u003c\/li\u003e\n\u003cli\u003eSignal isolation for PLC\/DCS analogue inputs\u003c\/li\u003e\n\u003cli\u003eSIL 2 temperature monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Sensor connects to terminals 1–4; output on terminals 7, 8, 9 (sink or source). Configure input type, range and fault behaviour with PACTware.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-UT2-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-UT2-Ex1 is a 1-channel isolated barrier universal temperature converter. It accepts thermocouple, RTD, potentiometer or millivolt inputs from the hazardous area and converts them into a 0\/4 … 20 mA current output for PLC, DCS or recorder inputs.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-UT2-Ex1 need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-UT2-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70157025_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-UT2-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/122811\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-UT2-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter\"\u003ePepperl+Fuchs KFD2-GUT-Ex1.D – Temperature Converter with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-UT2-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161089667397,"sku":"KFD2-UT2-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-ut2-ex1-universal-temperature-converter.jpg?v=1794323919"},{"product_id":"pepperl-fuchs-nbn40-l2-e2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBN40-L2-E2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBN40-L2-E2-V1 is a long-range 40 x 40 mm inductive proximity sensor with a 40 mm rated operating distance for non-flush mounting. It switches a PNP normally open output on a 3-wire DC circuit and is ideal where targets cannot be approached closely.\u003c\/p\u003e\n\u003cp\u003eA bidirectional, rotatable sensor head, four LEDs for 360° visibility and a quick mounting bracket make installation and diagnosis straightforward. The sensor is rated IP68 \/ IP69K and operates from 10 … 30 V DC.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBN40-L2-E2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e40 mm rated operating distance, non-flush mounting\u003c\/li\u003e\n\u003cli\u003ePNP normally open output, 3-wire DC\u003c\/li\u003e\n\u003cli\u003eBidirectional, rotatable sensor head\u003c\/li\u003e\n\u003cli\u003e4 LEDs for 360° visibility\u003c\/li\u003e\n\u003cli\u003eQuick mounting bracket\u003c\/li\u003e\n\u003cli\u003eIP68 \/ IP69K degree of protection\u003c\/li\u003e\n\u003cli\u003eM12 connector, 4-pin (V1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBN40-L2-E2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, 40 x 40 mm rectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 32.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eActual operating distance (sr)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e36 … 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNon-flush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, normally open (NO), 3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e10 … 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 180 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicators\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eLED green (power), LED yellow (switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePA (polyamide), sensing face PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 x 1 connector plug, 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 40 x 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e130 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP68 \/ IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA0000160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLong-range detection on conveyors and cranes\u003c\/li\u003e\n\u003cli\u003eVehicle and carriage position detection\u003c\/li\u003e\n\u003cli\u003eMaterial handling and logistics\u003c\/li\u003e\n\u003cli\u003eHeavy machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eFit using the quick mounting bracket and rotate the head to the required direction. Non-flush: keep the free zone around the sensing face clear of metal. Connect via an M12 4-pin cable socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBN40-L2-E2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBN40-L2-E2-V1 is a long-range 40 x 40 mm inductive proximity sensor with a 40 mm rated operating distance for non-flush mounting. It switches a PNP normally open output on a 3-wire DC circuit and is ideal where targets cannot be approached closely.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBN40-L2-E2-V1 need?\u003c\/h3\u003e\u003cp\u003e10 … 30 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBN40-L2-E2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/187484_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBN40-L2-E2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/14858\" target=\"_blank\" rel=\"noopener\"\u003eNBN40-L2-E2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn40-l2-a2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN40-L2-A2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn40-u4-uu-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN40-U4-UU – Inductive Proximity Sensor (AC\/DC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBN40-L2-E2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161089732933,"sku":"NBN40-L2-E2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbn40-l2-e2-v1-inductive-proximity-sensor.jpg?v=1794323921"},{"product_id":"pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, or accepts a 2-wire SMART current source, in the hazardous area and repeats the 4 … 20 mA signal to the safe area as either a current sink or current source output.\u003c\/p\u003e\n\u003cp\u003eHART communication is transferred bi-directionally, terminals with test points simplify maintenance, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508. It is supplied at 24 V DC via the Power Rail and carries ATEX and IECEx certification, including Ex ec installation in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC5-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA output, current sink or source\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC5-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.6 W at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA; ≥ 20 V at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA, sink or source (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 800 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCML 17 ATEX 2029X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; CML 17 ATEX 3028X — II 3G Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx CML 17.0015X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePressure, level and flow transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART-enabled instrument loops\u003c\/li\u003e\n\u003cli\u003eAnalogue input marshalling\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Field connection on terminals 1+, 2-, 3; output on 7, 8, 9 (sink or source arrangement per manual).\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC5-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, or accepts a 2-wire SMART current source, in the hazardous area and repeats the 4 … 20 mA signal to the safe area as either a current sink or current source output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC5-Ex1 need?\u003c\/h3\u003e\u003cp\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC5-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70124109_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/101414\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC5-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC5-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161089995077,"sku":"KFD2-STC5-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply.jpg?v=1794323923"},{"product_id":"pepperl-fuchs-nbb20-l2-a2-v1-inductive-proximity-sensor","title":"Pepperl+Fuchs NBB20-L2-A2-V1 – Inductive Proximity Sensor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NBB20-L2-A2-V1 is a 40 x 40 mm rectangular inductive proximity sensor with a 20 mm rated operating distance for flush mounting. It has a 4-wire DC configuration with complementary PNP outputs, providing both NO and NC switching signals at once.\u003c\/p\u003e\n\u003cp\u003eThe sensor head is bidirectional and rotatable so it can face five directions, four LEDs give 360° status visibility, and a quick mounting bracket speeds up installation. With IP68 \/ IP69K protection and a 10 … 30 V DC supply, it is well suited to conveyors, cranes and heavy-duty automation.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NBB20-L2-A2-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor\u003c\/li\u003e\n\u003cli\u003e20 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003e4-wire DC, complementary PNP outputs (NO + NC)\u003c\/li\u003e\n\u003cli\u003eBidirectional, rotatable sensor head\u003c\/li\u003e\n\u003cli\u003e4 LEDs for 360° visibility\u003c\/li\u003e\n\u003cli\u003eQuick mounting bracket\u003c\/li\u003e\n\u003cli\u003eIP68 \/ IP69K degree of protection\u003c\/li\u003e\n\u003cli\u003eM12 connector, 4-pin (V1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNBB20-L2-A2-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, 40 x 40 mm rectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 16.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eActual operating distance (sr)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e18 … 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePNP, complementary (NO\/NC), 4-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOperating voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e10 … 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 440 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIndicators\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eLED green (power), LED yellow (switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePA (polyamide), sensing face PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eM12 x 1 connector plug, 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 40 x 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e155 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP68 \/ IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eApprovals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus Listed; marine approval DNV GL TAA0000160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConveyors and material handling\u003c\/li\u003e\n\u003cli\u003eCranes, hoists and heavy machinery\u003c\/li\u003e\n\u003cli\u003eEnd-position detection on large metal targets\u003c\/li\u003e\n\u003cli\u003eLogistics and automated storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eFit using the quick mounting bracket; the head can be rotated to the required sensing direction. Flush design allows mounting in metal. Connect via an M12 4-pin cable socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NBB20-L2-A2-V1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NBB20-L2-A2-V1 is a 40 x 40 mm rectangular inductive proximity sensor with a 20 mm rated operating distance for flush mounting. It has a 4-wire DC configuration with complementary PNP outputs, providing both NO and NC switching signals at once.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the NBB20-L2-A2-V1 need?\u003c\/h3\u003e\u003cp\u003e10 … 30 V DC.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NBB20-L2-A2-V1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/187548_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NBB20-L2-A2-V1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/29195\" target=\"_blank\" rel=\"noopener\"\u003eNBB20-L2-A2-V1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbb20-l2-e2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBB20-L2-E2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-nbn40-l2-a2-v1-inductive-proximity-sensor\"\u003ePepperl+Fuchs NBN40-L2-A2-V1 – Inductive Proximity Sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NBB20-L2-A2-V1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161090191685,"sku":"NBB20-L2-A2-V1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nbb20-l2-a2-v1-inductive-proximity-sensor.jpg?v=1794323925"},{"product_id":"pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter","title":"Pepperl+Fuchs KFD2-UFC-Ex1.D – Universal Frequency Converter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values. It evaluates pulse and frequency signals from NAMUR sensors or dry contacts in the hazardous area over an input range of 1 mHz to 5 kHz and converts them into a 0\/4 … 20 mA analogue output.\u003c\/p\u003e\n\u003cp\u003eTwo relay contact outputs and a transistor output can be programmed as limit values for overspeed, underspeed or standstill monitoring, and a start-up override input suppresses alarms while machinery runs up. The module is supplied at 24 V DC via the Power Rail, configured by keypad or PACTware, and suitable for applications up to SIL 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-UFC-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Universal Frequency Converter\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003eInput frequency 1 mHz … 5 kHz\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs and 1 transistor output\u003c\/li\u003e\n\u003cli\u003eStart-up override input\u003c\/li\u003e\n\u003cli\u003eLine fault detection; up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-UFC-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel frequency converter with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital (pulse\/frequency) input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput I\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR (EN 60947-5-6) or mechanical contact, terminals 1+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.001 … 5000 Hz; pulse duration \u0026gt; 50 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eStart-up override 1 … 1000 s (non-intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 253 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eElectronic (transistor) output, passive, 40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput IV\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.1 % of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 99 ATEX 1471 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1885 X — II 3G Ex nA nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 04.0007, IECEx TSA 18.0007X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E223772)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSpeed and overspeed monitoring of pumps, fans and conveyors\u003c\/li\u003e\n\u003cli\u003eStandstill and underspeed detection\u003c\/li\u003e\n\u003cli\u003ePulse-output flowmeter rate signals\u003c\/li\u003e\n\u003cli\u003eSIL 2 speed monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide) with 24 V DC from the Power Rail or terminals 23+\/24-. Sensor connects to terminals 1+\/3-, start-up override to 13+\/14-. Relays on 10–12 and 16–18, transistor output on 19+\/20-, analogue output on 8+\/7-.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values. It evaluates pulse and frequency signals from NAMUR sensors or dry contacts in the hazardous area over an input range of 1 mHz to 5 kHz and converts them into a 0\/4 … 20 mA analogue output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-UFC-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/231194_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-UFC-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/48336\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-UFC-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfu8-ufc-ex1-d-frequency-converter\"\u003ePepperl+Fuchs KFU8-UFC-Ex1.D – Universal Frequency Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-UFC-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161090322757,"sku":"KFD2-UFC-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-ufc-ex1-d-universal-frequency-converter.jpg?v=1794323927"}],"url":"https:\/\/valvesuk.com\/collections\/accessories.oembed?page=4","provider":"Valves UK","version":"1.0","type":"link"}