{"title":"Intrinsically Safe (Ex) Products","description":"\u003cp\u003eBrowse intrinsically safe interface modules and NAMUR sensors for hazardous-area (Ex) applications at Valves UK. Always check the certificate data on each product page.\u003c\/p\u003e","products":[{"product_id":"pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier","title":"Pepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier from the K-System range. It transfers digital signals from NAMUR sensors or dry contacts located in a hazardous area to relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and power supply circuits.\u003c\/p\u003e\n\u003cp\u003eThe module is powered at 24 V DC via the Pepperl+Fuchs Power Rail or terminals, and its intrinsically safe [Ex ia] inputs are certified under ATEX and IECEx. Line fault detection (LFD), a reversible mode of operation set by DIP switch and suitability for applications up to SIL 2 (SC 3) to IEC\/EN 61508 make it a dependable interface for level, position and limit-switch signals in process plants.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SR2-Ex2.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Isolated Barrier Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier with relay contact outputs\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors (EN 60947-5-6) or dry contacts\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (lead breakage and short circuit)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation, configured by DIP switches\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified [Ex ia] inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SR2-Ex2.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching point \/ hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 … 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 7, 8, 9 and 10, 11, 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, systematic capability SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2080 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1493 X — II 3G Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0034, IECEx TUN 19.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFM (FM19US0207X), UL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHazardous-area limit switch and valve position feedback\u003c\/li\u003e\n\u003cli\u003eLevel switch signals from tanks and vessels in Ex zones\u003c\/li\u003e\n\u003cli\u003eInterfacing NAMUR proximity sensors to PLC and DCS digital inputs\u003c\/li\u003e\n\u003cli\u003eSafety instrumented functions up to SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on a 35 mm DIN rail in the safe area or, where permitted by the Ex ec certificate, in Zone 2. The unit can draw its 24 V DC supply from the Power Rail, which also carries the collective error message. Field wiring connects to terminals 1–6 and the relay outputs to terminals 7–12. Always follow the certificate, instruction manual and control drawings when designing intrinsically safe loops.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier from the K-System range. It transfers digital signals from NAMUR sensors or dry contacts located in a hazardous area to relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and power supply circuits.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SR2-Ex2.W need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/203355_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95426\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SR2-Ex2.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sra-ex4-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SRA-Ex4 – 4-Channel Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SR2-Ex2.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161026687301,"sku":"KFD2-SR2-Ex2.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier-switch-amplifier.jpg?v=1794323780"},{"product_id":"pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier","title":"Pepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts a NAMUR sensor or dry contact on its intrinsically safe input and switches a relay contact output, keeping input, output and supply circuits galvanically isolated with reinforced insulation.\u003c\/p\u003e\n\u003cp\u003ePart of the K-System, the module runs from 24 V DC via the Power Rail or terminals. Line fault detection, a reversible mode of operation selected by DIP switch and suitability up to SIL 2 (SC 3) to IEC\/EN 61508 make it well suited to single-point switching duties such as limit switches, level switches and valve position feedback.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SR2-Ex1.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier with relay contact output\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation via DIP switch\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified [Ex ia] input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SR2-Ex1.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 0.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1+, 2+, 3-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching point \/ hysteresis\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 … 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 × relay (terminals 7, 8, 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2080 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1493 X — II 3G Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0034, IECEx TUN 19.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFM (FM19US0207X), UL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle limit switch or proximity sensor signals from Ex zones\u003c\/li\u003e\n\u003cli\u003eValve open\/closed position indication\u003c\/li\u003e\n\u003cli\u003eLevel switch alarms to PLC and DCS inputs\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC supplied from the Power Rail or terminals 14+\/15-. Connect the field device to terminals 1+, 2+, 3- and the relay output to terminals 7, 8, 9. Configure mode of operation and line fault detection with the front DIP switches. Observe the ATEX\/IECEx certificate and instruction manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts a NAMUR sensor or dry contact on its intrinsically safe input and switches a relay contact output, keeping input, output and supply circuits galvanically isolated with reinforced insulation.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SR2-Ex1.W need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70101737_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/95424\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SR2-Ex1.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SR2-Ex1.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071513925,"sku":"KFD2-SR2-Ex1.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier.jpg?v=1794323888"},{"product_id":"pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters (and accepts 2-wire SMART current sources) in the hazardous area and repeats the 0\/4 … 20 mA signal to the safe area for PLC, DCS or indicator inputs.\u003c\/p\u003e\n\u003cp\u003eDigital HART communication is transferred bi-directionally, and terminals with test points simplify commissioning and loop checks. The module runs from 24 V DC via the Power Rail, its input is certified [Ex ia] under ATEX and IECEx, and it is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC4-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA output\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC4-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA (terminals 1+, 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 800 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHART bandwidth\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 7.5 kHz (-3 dB), field to control side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 99 ATEX 7060 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 04.0016X, IECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePressure, level and flow transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART-enabled instrument loops\u003c\/li\u003e\n\u003cli\u003eAnalogue input marshalling for PLC\/DCS\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Connect 2-wire transmitters to terminals 1+\/3, 3-wire transmitters to 1+\/2-\/3, or current sources to 5-\/6+. The 0\/4–20 mA output is on terminals 7-\/8+. Check loop parameters (Uo 25.4 V, Io 86.8 mA, Po 551 mW for terminals 1+\/3-) against the field device certificate.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC4-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters (and accepts 2-wire SMART current sources) in the hazardous area and repeats the 0\/4 … 20 mA signal to the safe area for PLC, DCS or indicator inputs.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC4-Ex1 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC4-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/283672_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/75019\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC4-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC4-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071546693,"sku":"KFD2-STC4-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply.jpg?v=1794323890"},{"product_id":"pepperl-fuchs-kcd2-sr-ex2-isolated-barrier","title":"Pepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KCD2-SR-Ex2 is a 2-channel isolated barrier switch amplifier in the space-saving 12.5 mm K-System housing. It transfers switching signals from NAMUR sensors or dry contacts in the hazardous area to two relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003cp\u003ePowered at 24 V DC via the Power Rail or terminals, the module provides line fault detection on each input and is suitable for applications up to SIL 2 (SC 3) to IEC\/EN 61508. Its narrow width allows high-density installation in marshalling and control cabinets, and its ATEX\/IECEx certification includes mounting in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-SR-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Isolated Barrier Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier in a 12.5 mm wide housing\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified, Zone 2 mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKCD2-SR-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 46 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 900 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I ≥ 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 5, 6 and 7, 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e250 V AC \/ 2 A \/ cos φ \u0026gt; 0.75; 30 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e12.5 x 119 x 114 mm (W x H x D), housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBASEEFA 06 ATEX 0092 X — II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 06.0025 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL\/cULus (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh-density digital input marshalling\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor and limit switch interfacing\u003c\/li\u003e\n\u003cli\u003eValve position feedback in Ex areas\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eMount on a 35 mm DIN rail; supply 24 V DC via the Power Rail or terminals 9+\/10-. Field circuits connect to terminals 1–4 and the relay outputs to terminals 5–8. Functions are set with DIP switches. The device may be installed in Zone 2 under the Ex ec certification — follow the certificate and manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KCD2-SR-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KCD2-SR-Ex2 is a 2-channel isolated barrier switch amplifier in the space-saving 12.5 mm K-System housing. It transfers switching signals from NAMUR sensors or dry contacts in the hazardous area to two relay contact outputs in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KCD2-SR-Ex2 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KCD2-SR-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70112153_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KCD2-SR-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/99636\" target=\"_blank\" rel=\"noopener\"\u003eKCD2-SR-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-stc-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KCD2-SR-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161071579461,"sku":"KCD2-SR-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier-switch-amplifier.jpg?v=1794323892"},{"product_id":"pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier-115v-ac","title":"Pepperl+Fuchs KFA5-SR2-Ex2.W – Switch Amplifier (115 V AC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier designed for installations with a 115 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, maintaining reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003cp\u003eLine fault detection identifies lead breakage and short circuits on the field wiring, the mode of operation is reversible via DIP switches, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511. It is a practical choice where control panels are AC powered rather than fed from a 24 V DC Power Rail.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA5-SR2-Ex2.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier (115 V AC)\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e115 V AC supply (103.5 … 126 V AC, 45 … 65 Hz)\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFA5-SR2-Ex2.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 7, 8, 9 and 10, 11, 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 126.5 V AC \/ 4 A; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2081 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC-powered control panels interfacing Ex-area switches\u003c\/li\u003e\n\u003cli\u003eLimit switch and valve position signals\u003c\/li\u003e\n\u003cli\u003eLevel switch alarms\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting in the safe area with 115 V AC supply on terminals 14 and 15 (this model does not use the Power Rail for supply). Field devices connect to terminals 1–6 and relay outputs to terminals 7–12. Configure via DIP switches and follow the certificate and manual for intrinsically safe wiring.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFA5-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier designed for installations with a 115 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, maintaining reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFA5-SR2-Ex2.W need?\u003c\/h3\u003e\u003cp\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFA5-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/103370_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFA5-SR2-Ex2.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/3134\" target=\"_blank\" rel=\"noopener\"\u003eKFA5-SR2-Ex2.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa6-sr2-ex2-w-switch-amplifier-230v-ac\"\u003ePepperl+Fuchs KFA6-SR2-Ex2.W – Switch Amplifier (230 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFA5-SR2-Ex2.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161072824645,"sku":"KFA5-SR2-Ex2.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier.jpg?v=1794323894"},{"product_id":"pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003cp\u003eHART communication is passed bi-directionally, and terminals with test points support commissioning and maintenance. The unit is supplied at 24 V DC via the Power Rail, is ATEX and IECEx certified for [Ex ia] inputs and is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC4-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 2-Channel SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA output per channel\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC4-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA from 2-wire transmitters (terminals 1+, 3-; 4+, 6-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA per channel (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 550 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 99 ATEX 7025 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 04.0015X, IECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo analogue transmitter loops per module\u003c\/li\u003e\n\u003cli\u003ePressure, level and temperature transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART asset management access\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail. Transmitters connect to terminals 1+\/3- (channel I) and 4+\/6- (channel II); outputs are on 7-\/8+ and 10-\/11+. Observe the certificate and safety manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC4-Ex2 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/283699_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/75015\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC4-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC4-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161076232517,"sku":"KFD2-STC4-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc4-ex2-2-channel-smart-transmitter-power-supply.jpg?v=1794323901"},{"product_id":"pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier-115v-ac","title":"Pepperl+Fuchs KFA5-SR2-Ex1.W – Switch Amplifier (115 V AC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for 115 V AC powered installations. It reads a NAMUR sensor or dry contact located in a hazardous area and switches a relay contact output in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003cp\u003eThe unit provides line fault detection, a reversible mode of operation selected by DIP switch, and suitability for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511. Its intrinsically safe input is certified under ATEX and IECEx for Ex ia applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA5-SR2-Ex1.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier (115 V AC)\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e115 V AC supply (103.5 … 126 V AC)\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003eRelay contact output\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFA5-SR2-Ex1.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1+, 2+, 3-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1 × relay (terminals 7, 8, 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 126.5 V AC \/ 4 A; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2081 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle-point switching signals from Ex zones in AC-powered panels\u003c\/li\u003e\n\u003cli\u003eValve position feedback\u003c\/li\u003e\n\u003cli\u003eLevel and limit switch alarms\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 115 V AC supply on terminals 14\/15. Connect the field device to terminals 1+, 2+, 3- and the relay output to terminals 7, 8, 9. Configure with the front DIP switches and follow the certificate and instruction manual for intrinsically safe loops.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFA5-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFA5-SR2-Ex1.W is a 1-channel isolated barrier switch amplifier for 115 V AC powered installations. It reads a NAMUR sensor or dry contact located in a hazardous area and switches a relay contact output in the safe area, with reinforced galvanic isolation between input, output and supply.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFA5-SR2-Ex1.W need?\u003c\/h3\u003e\u003cp\u003e103.5 … 126 V AC, 45 … 65 Hz (terminals 14, 15).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFA5-SR2-Ex1.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/103371_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFA5-SR2-Ex1.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/3132\" target=\"_blank\" rel=\"noopener\"\u003eKFA5-SR2-Ex1.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex2.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex1-w-switch-amplifier\"\u003ePepperl+Fuchs KFD2-SR2-Ex1.W – Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFA5-SR2-Ex1.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161083998533,"sku":"KFA5-SR2-Ex1.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfa5-sr2-ex1-w-switch-amplifier.jpg?v=1794323909"},{"product_id":"pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-CRG2-Ex1.D is a 1-channel isolated barrier transmitter power supply with trip values. It powers 2-wire and 3-wire transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 0\/4 … 20 mA analogue output together with two relay contact outputs for high\/low alarms.\u003c\/p\u003e\n\u003cp\u003eAlarm set points, energised\/de-energised delays (0 … 250 s) and a linearisation function of up to 20 points are programmed via the front keypad and display or with PACTware. Line fault detection monitors the input circuit, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-CRG2-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Transmitter Power Supply with Trip Values\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eInput for 2-wire and 3-wire transmitters and 2-wire current sources\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA analogue output\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs with programmable high\/low alarms\u003c\/li\u003e\n\u003cli\u003eAdjustable energised\/de-energised delay\u003c\/li\u003e\n\u003cli\u003eLinearisation function (max. 20 points)\u003c\/li\u003e\n\u003cli\u003eLine fault detection; up to SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-CRG2-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel transmitter power supply with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 15 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I \u0026lt; 0.2 mA; short circuit I \u0026gt; 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 253 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDelay\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 250 s, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 01 ATEX 1701 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1885 X — II 3G Ex nA nC IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 09.0007, IECEx TSA 18.0007X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E223772)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLevel and pressure transmitters with local high\/low alarm relays\u003c\/li\u003e\n\u003cli\u003eAnalogue signal isolation with limit monitoring\u003c\/li\u003e\n\u003cli\u003ePump and process protection trips\u003c\/li\u003e\n\u003cli\u003eSIL 2 limit value monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide) with 24 V DC from the Power Rail or terminals 23+\/24-. Transmitter connects to terminals 1, 2, 3; relays to 10–12 and 16–18; analogue output to 8+\/7-. Configure via the keypad or PACTware using the programming socket.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-CRG2-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-CRG2-Ex1.D is a 1-channel isolated barrier transmitter power supply with trip values. It powers 2-wire and 3-wire transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 0\/4 … 20 mA analogue output together with two relay contact outputs for high\/low alarms.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-CRG2-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-CRG2-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/255620_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/58378\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-CRG2-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter\"\u003ePepperl+Fuchs KFD2-UFC-Ex1.D – Universal Frequency Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter\"\u003ePepperl+Fuchs KFD2-GUT-Ex1.D – Temperature Converter with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-CRG2-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161085276485,"sku":"KFD2-CRG2-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply-with-trip-values.jpg?v=1794323911"},{"product_id":"pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, and accepts 2-wire SMART current sources, in the hazardous area, repeating each 4 … 20 mA signal to the safe area as a current sink or current source output.\u003c\/p\u003e\n\u003cp\u003eHART communication is transferred bi-directionally and terminals with test points simplify loop checks. Supplied at 24 V DC via the Power Rail, the module is ATEX and IECEx certified, suitable for applications up to SIL 2 (SC 3) to IEC\/EN 61508, and can also be installed in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC5-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 2-Channel SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA output, current sink or source\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC5-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 2.6 W at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA; ≥ 20 V at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA, sink or source (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C (up to 70 °C with mounting conditions per manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCML 17 ATEX 2031X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; CML 17 ATEX 3030X — II 3G Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx CML 17.0016X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo analogue transmitter loops per module\u003c\/li\u003e\n\u003cli\u003eFlow, pressure and level measurement in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART asset management\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail. Sink or source output is selected by the output terminal arrangement (see manual). Observe the certificate, loop parameters and safety manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC5-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, and accepts 2-wire SMART current sources, in the hazardous area, repeating each 4 … 20 mA signal to the safe area as a current sink or current source output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC5-Ex2 need?\u003c\/h3\u003e\u003cp\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC5-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/203645_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/63975\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC5-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC5-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161088749893,"sku":"KFD2-STC5-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc5-ex2-2-channel-smart-transmitter-power-supply.jpg?v=1794323916"},{"product_id":"pepperl-fuchs-kfd2-ut2-ex1-temperature-converter","title":"Pepperl+Fuchs KFD2-UT2-Ex1 – Universal Temperature Converter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-UT2-Ex1 is a 1-channel isolated barrier universal temperature converter. It accepts thermocouple, RTD, potentiometer or millivolt inputs from the hazardous area and converts them into a 0\/4 … 20 mA current output for PLC, DCS or recorder inputs.\u003c\/p\u003e\n\u003cp\u003eThe output can operate in sink or source mode, and line fault and sensor burnout detection drive a NAMUR NE43 fault signal. The module is configured with PACTware, supplied at 24 V DC via the Power Rail or terminals, and suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-UT2-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Universal Temperature Converter\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eThermocouple, RTD, potentiometer or voltage input\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output, sink or source\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (internal or external)\u003c\/li\u003e\n\u003cli\u003eLine fault and sensor burnout detection\u003c\/li\u003e\n\u003cli\u003eConfigured with PACTware\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-UT2-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel temperature converter \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 0.98 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRTD inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePt10–Pt1000 (EN 60751), Cu and other types; 2-, 3- or 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eThermocouple inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTypes B, E, J, K, N, R, S, T (IEC 584-1) and L (DIN 43710)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePotentiometer 0 … 20 kΩ; voltage -100 … 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA; source load 0 … 550 Ω or sink mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFault signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDownscale 0 or 2 mA, upscale 21.5 mA (NAMUR NE43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePACTware via programming socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 130 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCESI 04 ATEX 143 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1797 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 07.0003, IECEx CML 16.0126X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTemperature measurement with RTDs or thermocouples in Ex zones\u003c\/li\u003e\n\u003cli\u003eReactor, vessel and pipeline temperature loops\u003c\/li\u003e\n\u003cli\u003eSignal isolation for PLC\/DCS analogue inputs\u003c\/li\u003e\n\u003cli\u003eSIL 2 temperature monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Sensor connects to terminals 1–4; output on terminals 7, 8, 9 (sink or source). Configure input type, range and fault behaviour with PACTware.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-UT2-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-UT2-Ex1 is a 1-channel isolated barrier universal temperature converter. It accepts thermocouple, RTD, potentiometer or millivolt inputs from the hazardous area and converts them into a 0\/4 … 20 mA current output for PLC, DCS or recorder inputs.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-UT2-Ex1 need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-UT2-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70157025_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-UT2-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/122811\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-UT2-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter\"\u003ePepperl+Fuchs KFD2-GUT-Ex1.D – Temperature Converter with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-UT2-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161089667397,"sku":"KFD2-UT2-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-ut2-ex1-universal-temperature-converter.jpg?v=1794323919"},{"product_id":"pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC5-Ex1 – SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, or accepts a 2-wire SMART current source, in the hazardous area and repeats the 4 … 20 mA signal to the safe area as either a current sink or current source output.\u003c\/p\u003e\n\u003cp\u003eHART communication is transferred bi-directionally, terminals with test points simplify maintenance, and the module is suitable for applications up to SIL 2 to IEC\/EN 61508. It is supplied at 24 V DC via the Power Rail and carries ATEX and IECEx certification, including Ex ec installation in Zone 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC5-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire and 3-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eAccepts 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA output, current sink or source\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC5-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.6 W at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA; ≥ 20 V at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA, sink or source (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 800 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCML 17 ATEX 2029X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; CML 17 ATEX 3028X — II 3G Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx CML 17.0015X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePressure, level and flow transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART-enabled instrument loops\u003c\/li\u003e\n\u003cli\u003eAnalogue input marshalling\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. Field connection on terminals 1+, 2-, 3; output on 7, 8, 9 (sink or source arrangement per manual).\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC5-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC5-Ex1 is a 1-channel isolated barrier SMART transmitter power supply. It powers 2-wire and 3-wire SMART transmitters, or accepts a 2-wire SMART current source, in the hazardous area and repeats the 4 … 20 mA signal to the safe area as either a current sink or current source output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC5-Ex1 need?\u003c\/h3\u003e\u003cp\u003e18 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC5-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70124109_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC5-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/101414\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC5-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC5-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161089995077,"sku":"KFD2-STC5-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc5-ex1-smart-transmitter-power-supply.jpg?v=1794323923"},{"product_id":"pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter","title":"Pepperl+Fuchs KFD2-UFC-Ex1.D – Universal Frequency Converter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values. It evaluates pulse and frequency signals from NAMUR sensors or dry contacts in the hazardous area over an input range of 1 mHz to 5 kHz and converts them into a 0\/4 … 20 mA analogue output.\u003c\/p\u003e\n\u003cp\u003eTwo relay contact outputs and a transistor output can be programmed as limit values for overspeed, underspeed or standstill monitoring, and a start-up override input suppresses alarms while machinery runs up. The module is supplied at 24 V DC via the Power Rail, configured by keypad or PACTware, and suitable for applications up to SIL 2.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-UFC-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Universal Frequency Converter\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003eInput frequency 1 mHz … 5 kHz\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs and 1 transistor output\u003c\/li\u003e\n\u003cli\u003eStart-up override input\u003c\/li\u003e\n\u003cli\u003eLine fault detection; up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-UFC-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel frequency converter with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital (pulse\/frequency) input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput I\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR (EN 60947-5-6) or mechanical contact, terminals 1+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.001 … 5000 Hz; pulse duration \u0026gt; 50 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eStart-up override 1 … 1000 s (non-intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 253 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eElectronic (transistor) output, passive, 40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput IV\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.1 % of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 99 ATEX 1471 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 02 ATEX 1885 X — II 3G Ex nA nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 04.0007, IECEx TSA 18.0007X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E223772)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSpeed and overspeed monitoring of pumps, fans and conveyors\u003c\/li\u003e\n\u003cli\u003eStandstill and underspeed detection\u003c\/li\u003e\n\u003cli\u003ePulse-output flowmeter rate signals\u003c\/li\u003e\n\u003cli\u003eSIL 2 speed monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide) with 24 V DC from the Power Rail or terminals 23+\/24-. Sensor connects to terminals 1+\/3-, start-up override to 13+\/14-. Relays on 10–12 and 16–18, transistor output on 19+\/20-, analogue output on 8+\/7-.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values. It evaluates pulse and frequency signals from NAMUR sensors or dry contacts in the hazardous area over an input range of 1 mHz to 5 kHz and converts them into a 0\/4 … 20 mA analogue output.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-UFC-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/231194_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-UFC-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/48336\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-UFC-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfu8-ufc-ex1-d-frequency-converter\"\u003ePepperl+Fuchs KFU8-UFC-Ex1.D – Universal Frequency Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-UFC-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161090322757,"sku":"KFD2-UFC-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-ufc-ex1-d-universal-frequency-converter.jpg?v=1794323927"},{"product_id":"pepperl-fuchs-kfd2-sra-ex4-switch-amplifier","title":"Pepperl+Fuchs KFD2-SRA-Ex4 – 4-Channel Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SRA-Ex4 is a 4-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts NAMUR sensors or dry contacts and provides four relay contact outputs in a single 20 mm wide K-System module.\u003c\/p\u003e\n\u003cp\u003ePepperl+Fuchs 2:1 technology lets two field devices share one pair of field wires, reducing field wiring by up to 50 %. The module is supplied at 24 V DC via the Power Rail or terminals, offers line fault detection and a reversible mode of operation, and its inputs are ATEX and IECEx certified for Ex ia applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SRA-Ex4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 4-Channel Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e4-channel isolated barrier in one 20 mm module\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2:1 technology — up to 50 % less field wiring\u003c\/li\u003e\n\u003cli\u003e4 relay contact outputs\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SRA-Ex4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e45 … 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1–6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.15 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 × relay (terminals 7–12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz (non-AC operation), ≤ 3 Hz (AC operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eZELM 99 ATEX 0009 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 04.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh channel-count digital input systems\u003c\/li\u003e\n\u003cli\u003eValve position feedback with two sensors per valve\u003c\/li\u003e\n\u003cli\u003eReducing field cabling in retrofit projects\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor interfacing to PLC\/DCS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. 2:1 operation is set by DIP switch; see the manual for the required field circuit arrangement. Relay outputs connect to terminals 7–12. Follow the certificate and manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SRA-Ex4?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SRA-Ex4 is a 4-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts NAMUR sensors or dry contacts and provides four relay contact outputs in a single 20 mm wide K-System module.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SRA-Ex4 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SRA-Ex4?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/190176_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SRA-Ex4 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/35550\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SRA-Ex4 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier\"\u003ePepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SRA-Ex4. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161092288837,"sku":"KFD2-SRA-Ex4","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sra-ex4-4-channel-switch-amplifier.jpg?v=1794323932"},{"product_id":"pepperl-fuchs-kfu8-ufc-ex1-d-frequency-converter","title":"Pepperl+Fuchs KFU8-UFC-Ex1.D – Universal Frequency Converter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFU8-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values and a universal power supply. It accepts 20 … 90 V DC or 48 … 253 V AC, making it suitable for panels where a 24 V DC Power Rail is not available.\u003c\/p\u003e\n\u003cp\u003eIt evaluates pulse and frequency signals from NAMUR sensors or dry contacts in the hazardous area (1 mHz … 5 kHz), converts them into a 0\/4 … 20 mA output, and provides two relay outputs and a transistor output for programmable limit values. A start-up override input, line fault detection and suitability up to SIL 2 complete the specification.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFU8-UFC-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Universal Frequency Converter\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eUniversal supply: 20 … 90 V DC \/ 48 … 253 V AC\u003c\/li\u003e\n\u003cli\u003eInput for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003eInput frequency 1 mHz … 5 kHz\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output\u003c\/li\u003e\n\u003cli\u003e2 relay outputs and 1 transistor output\u003c\/li\u003e\n\u003cli\u003eStart-up override; up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFU8-UFC-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel frequency converter with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital (pulse\/frequency) input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 90 V DC \/ 48 … 253 V AC, 50 … 60 Hz (terminals 23, 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 2.2 W \/ 3 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput I\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR (EN 60947-5-6) or mechanical contact, terminals 1+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.001 … 5000 Hz; pulse duration \u0026gt; 50 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eStart-up override 1 … 1000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 250 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eElectronic (transistor) output, passive, 40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput IV\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0.1 % of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 99 ATEX 1471 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 04.0007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSpeed and overspeed monitoring in AC- or DC-powered panels\u003c\/li\u003e\n\u003cli\u003eStandstill and underspeed detection\u003c\/li\u003e\n\u003cli\u003ePulse flowmeter rate conversion\u003c\/li\u003e\n\u003cli\u003eSIL 2 speed monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide); connect the universal supply to terminals 23\/24 (not supplied via Power Rail). Sensor on 1+\/3-, start-up override on 13+\/14-, relays on 10–12 and 16–18, transistor output on 19+\/20-, analogue output on 8+\/7-.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFU8-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFU8-UFC-Ex1.D is a 1-channel isolated barrier frequency converter with trip values and a universal power supply. It accepts 20 … 90 V DC or 48 … 253 V AC, making it suitable for panels where a 24 V DC Power Rail is not available.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFU8-UFC-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 90 V DC \/ 48 … 253 V AC, 50 … 60 Hz (terminals 23, 24).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFU8-UFC-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/231197_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFU8-UFC-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/48338\" target=\"_blank\" rel=\"noopener\"\u003eKFU8-UFC-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-ufc-ex1-d-frequency-converter\"\u003ePepperl+Fuchs KFD2-UFC-Ex1.D – Universal Frequency Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFU8-UFC-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161094418757,"sku":"KFU8-UFC-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfu8-ufc-ex1-d-universal-frequency-converter.jpg?v=1794323936"},{"product_id":"pepperl-fuchs-kfa6-sr2-ex2-w-switch-amplifier-230v-ac","title":"Pepperl+Fuchs KFA6-SR2-Ex2.W – Switch Amplifier (230 V AC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFA6-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier powered from a 230 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, with reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003cp\u003eWith line fault detection, a reversible mode of operation and suitability for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511, it suits mains-powered control panels that need to interface Ex-area switching devices without a separate 24 V DC supply.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA6-SR2-Ex2.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Switch Amplifier (230 V AC)\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e230 V AC supply (207 … 253 V AC, 45 … 65 Hz)\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFA6-SR2-Ex2.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e207 … 253 V AC, 45 … 65 Hz (terminals 14, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact; approx. 8 V DC \/ 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.1 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 × relay (terminals 7, 8, 9 and 10, 11, 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 126.5 V AC \/ 4 A; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2081 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e230 V AC powered control panels\u003c\/li\u003e\n\u003cli\u003eLimit and level switch signals from Ex zones\u003c\/li\u003e\n\u003cli\u003eValve position feedback\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 230 V AC on terminals 14\/15. Field devices connect to terminals 1–6, relay outputs to terminals 7–12. Follow the certificate and instruction manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFA6-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFA6-SR2-Ex2.W is a 2-channel isolated barrier switch amplifier powered from a 230 V AC supply. It transfers digital signals from NAMUR sensors or dry contacts in hazardous areas to two relay contact outputs, with reinforced galvanic isolation between input, output and supply circuits.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFA6-SR2-Ex2.W need?\u003c\/h3\u003e\u003cp\u003e207 … 253 V AC, 45 … 65 Hz (terminals 14, 15).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFA6-SR2-Ex2.W?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/103373_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFA6-SR2-Ex2.W datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/3138\" target=\"_blank\" rel=\"noopener\"\u003eKFA6-SR2-Ex2.W on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfa5-sr2-ex2-w-switch-amplifier-115v-ac\"\u003ePepperl+Fuchs KFA5-SR2-Ex2.W – Switch Amplifier (115 V AC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFA6-SR2-Ex2.W. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161096286533,"sku":"KFA6-SR2-Ex2.W","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfa6-sr2-ex2-w-switch-amplifier.jpg?v=1794323938"},{"product_id":"pepperl-fuchs-kcd2-stc-ex1-smart-transmitter-power-supply","title":"Pepperl+Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KCD2-STC-Ex1 is a 1-channel isolated barrier SMART transmitter power supply in the compact 12.5 mm K-System housing. It powers 2-wire SMART transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 4 … 20 mA or 1 … 5 V output to the control system.\u003c\/p\u003e\n\u003cp\u003eThe output can operate in source or sink mode, HART communication is supported, and the device is suitable for applications up to SIL 2 (SC 3) to IEC\/EN 61508. Supplied at 24 V DC via the Power Rail, it carries ATEX, IECEx, FM and UL approvals and allows high packing density in control cabinets.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KCD2-STC-Ex1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier, 12.5 mm housing\u003c\/li\u003e\n\u003cli\u003eInput for 2-wire SMART transmitters and current sources\u003c\/li\u003e\n\u003cli\u003eOutput 4 … 20 mA or 1 … 5 V\u003c\/li\u003e\n\u003cli\u003eSource or sink output mode\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX, IECEx, FM and UL approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKCD2-STC-Ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 … 20 mA (limited to approx. 26 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 15 V at 20 mA; ≥ 18 V at 4 mA (terminals 1+, 2-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSource: 4 … 20 mA or 1 … 5 V; sink: 4 … 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 350 Ω (source mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 0.1 % of full scale at 20 °C (4 … 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2, SC 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-40 … 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e12.5 x 119 x 114 mm (W x H x D), housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eCESI 06 ATEX 021 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; CESI 19 ATEX 021 X — II 3G Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx CES 06.0001X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFM (FM 18 CA 0116 X, FM 19 US 0117 X), UL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh-density analogue input marshalling\u003c\/li\u003e\n\u003cli\u003e2-wire transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART instrument loops\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 9+\/10-. Field connection on terminals 1+\/2- (transmitter) or 3+\/4- (current source); output on 5-\/6+ (5-\/8+ with internal HART resistor). Output mode is selected by DIP switch.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KCD2-STC-Ex1?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KCD2-STC-Ex1 is a 1-channel isolated barrier SMART transmitter power supply in the compact 12.5 mm K-System housing. It powers 2-wire SMART transmitters, or accepts 2-wire current sources, in the hazardous area and provides a 4 … 20 mA or 1 … 5 V output to the control system.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KCD2-STC-Ex1 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 9+, 10-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KCD2-STC-Ex1?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70150439_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KCD2-STC-Ex1 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/120032\" target=\"_blank\" rel=\"noopener\"\u003eKCD2-STC-Ex1 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier\"\u003ePepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KCD2-STC-Ex1. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161104904517,"sku":"KCD2-STC-Ex1","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kcd2-stc-ex1-smart-transmitter-power-supply.jpg?v=1794323946"},{"product_id":"pepperl-fuchs-kfd2-vr4-ex1-26-voltage-repeater","title":"Pepperl+Fuchs KFD2-VR4-Ex1.26 – Voltage Repeater","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-VR4-Ex1.26 is a 1-channel isolated barrier voltage repeater designed for vibration sensor signals. It supplies the field sensor (voltage or current supply) and transfers its 0 … -20 V signal from the hazardous area to the safe area with high bandwidth and low error.\u003c\/p\u003e\n\u003cp\u003eTypical applications include eddy-current proximity probes and accelerometers used in machine condition monitoring. The module is powered at 24 V DC via the Power Rail, is ATEX and IECEx certified for Ex ia inputs, and is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-VR4-Ex1.26\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Voltage Repeater\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eVoltage input 0 … -20 V\u003c\/li\u003e\n\u003cli\u003eInputs for vibration sensors\u003c\/li\u003e\n\u003cli\u003eVoltage or current field supply\u003c\/li\u003e\n\u003cli\u003eVoltage output 0 … -20 V\u003c\/li\u003e\n\u003cli\u003eCut-off frequency 10 kHz (-0.1 dB)\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-VR4-Ex1.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel voltage repeater \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 11+, 12-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 1.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eTransmission range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput resistance\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 0 V; load ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eCut-off frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e10 kHz (-0.1 dB), 20 kHz (-1 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDC transfer error\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 10 mV (10 kΩ load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 02 ATEX 7206 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC; DMT 01 ATEX E 133 — I (M1) [Ex ia] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 05.0078, IECEx BAS 10.0085X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMachine vibration monitoring (proximity probes, accelerometers)\u003c\/li\u003e\n\u003cli\u003eTurbine, compressor and pump condition monitoring\u003c\/li\u003e\n\u003cli\u003eInterfacing Ex-area vibration sensors to monitoring systems\u003c\/li\u003e\n\u003cli\u003eSIL 2 protection loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 11+\/12-. Sensor connects to terminals 1–6 according to sensor type (common terminal 4); output on 7-\/8+. Check the monitor input impedance against the output data in the manual.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-VR4-Ex1.26?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-VR4-Ex1.26 is a 1-channel isolated barrier voltage repeater designed for vibration sensor signals. It supplies the field sensor (voltage or current supply) and transfers its 0 … -20 V signal from the hazardous area to the safe area with high bandwidth and low error.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-VR4-Ex1.26 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 11+, 12-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-VR4-Ex1.26?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70107327_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-VR4-Ex1.26 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/97249\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-VR4-Ex1.26 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd0-sd2-ex2-1045-solenoid-driver\"\u003ePepperl+Fuchs KFD0-SD2-Ex2.1045 – Solenoid Driver\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-eb2-power-feed-module\"\u003ePepperl+Fuchs KFD2-EB2 – Power Feed Module\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-VR4-Ex1.26. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161106444613,"sku":"KFD2-VR4-Ex1.26","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-vr4-ex1-26-voltage-repeater.jpg?v=1794323948"},{"product_id":"pepperl-fuchs-nj2-v3-n-inductive-proximity-sensor","title":"Pepperl+Fuchs NJ2-V3-N – Inductive Proximity Sensor (NAMUR, SIL 2)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs NJ2-V3-N is a compact inductive proximity sensor with a NAMUR output and a 2 mm rated operating distance for flush mounting. NAMUR sensors are designed to be connected to an isolated barrier or switch amplifier, which makes the NJ2-V3-N a common choice for position detection in hazardous areas.\u003c\/p\u003e\n\u003cp\u003eThe sensor is usable up to SIL 2 to IEC 61508, is suitable for 2:1 technology, and carries ATEX and IECEx certification for equipment protection levels Ga, Gb and Da (IECEx also Mb). Its small 27.8 x 16 x 10.2 mm PBT housing with integral cable fits tight spaces such as valve position indicators.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NJ2-V3-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Inductive Proximity Sensor (NAMUR, SIL 2)\u003c\/li\u003e\n\u003cli\u003eNAMUR output (EN 60947-5-6)\u003c\/li\u003e\n\u003cli\u003e2 mm rated operating distance, flush mounting\u003c\/li\u003e\n\u003cli\u003eUsable up to SIL 2 to IEC 61508\u003c\/li\u003e\n\u003cli\u003eSuitable for 2:1 technology\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified (EPL Ga, Gb, Da)\u003c\/li\u003e\n\u003cli\u003eCompact PBT housing, IP67\u003c\/li\u003e\n\u003cli\u003eAmbient temperature -25 … 100 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNJ2-V3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eInductive proximity sensor, NAMUR, compact rectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated operating distance (sn)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAssured operating distance (sa)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 1.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR, normally closed (NC), 2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e8.2 V (Ri approx. 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eCurrent\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 3 mA target not detected; ≤ 1 mA target detected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eHousing \/ sensing face\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePVC cable, 130 mm, 0.14 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e27.8 x 16 x 10.2 mm (W x L x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-25 … 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePTB 00 ATEX 2032 X (EPL Ga, Gb, Da)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx PTB 11.0021X (EPL Ga, Gb, Da, Mb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ecULus; ANZEx 19.3001X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eValve position feedback in hazardous areas\u003c\/li\u003e\n\u003cli\u003ePosition detection in Ex zones via isolated barriers\u003c\/li\u003e\n\u003cli\u003eSIL 2 safety loops\u003c\/li\u003e\n\u003cli\u003eCompact installations in process equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eConnect to a NAMUR-input isolated barrier or switch amplifier (for example the Pepperl+Fuchs KFD2-SR2 series). For hazardous-area use, follow the EU-type examination certificate and observe the permissible ambient temperature for the connected circuit's parameters.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs NJ2-V3-N?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs NJ2-V3-N is a compact inductive proximity sensor with a NAMUR output and a 2 mm rated operating distance for flush mounting. NAMUR sensors are designed to be connected to an isolated barrier or switch amplifier, which makes the NJ2-V3-N a common choice for position detection in hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the NJ2-V3-N?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/70133090_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs NJ2-V3-N datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/103626\" target=\"_blank\" rel=\"noopener\"\u003eNJ2-V3-N on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier\"\u003ePepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs NJ2-V3-N. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161106772293,"sku":"NJ2-V3-N","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-nj2-v3-n-inductive-proximity-sensor.jpg?v=1794323950"},{"product_id":"pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter","title":"Pepperl+Fuchs KFD2-GUT-Ex1.D – Temperature Converter with Trip Values","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-GUT-Ex1.D is a 1-channel isolated barrier temperature converter with trip values. It accepts thermocouple (including redundant TC), RTD, potentiometer or voltage inputs from the hazardous area and provides a 0\/4 … 20 mA analogue output plus two relay contact outputs for temperature alarms.\u003c\/p\u003e\n\u003cp\u003eConfiguration is via the front keypad and display or PACTware, and line fault and sensor burnout detection are built in. Supplied at 24 V DC via the Power Rail, the module is ATEX and IECEx certified and suitable for applications up to SIL 2 to IEC\/EN 61508 \/ IEC\/EN 61511.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-GUT-Ex1.D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Temperature Converter with Trip Values\u003c\/li\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eThermocouple, RTD, potentiometer or voltage input\u003c\/li\u003e\n\u003cli\u003eRedundant thermocouple input\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA current output\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs for trip values\u003c\/li\u003e\n\u003cli\u003eKeypad\/display or PACTware configuration\u003c\/li\u003e\n\u003cli\u003eLine fault and burnout detection; up to SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-GUT-Ex1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1-channel temperature converter with trip values \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRTD inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePt100, Pt500, Pt1000, Ni100, Ni1000; 2-, 3- or 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eThermocouple inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTypes B, E, J, K, L, N, R, S, T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther inputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePotentiometer 0.8 … 20 kΩ; voltage 0 … 10 V, 2 … 10 V, 0 … 1 V, -100 … 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs I, II\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eRelay; 250 V AC \/ 2 A \/ cos φ ≥ 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput III\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 20 mA or 4 … 20 mA, load max. 650 Ω; NE43 fault signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eFront keypad and display, or PACTware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508 \/ IEC\/EN 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e40 x 119 x 115 mm (W x H x D), housing type C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTÜV 03 ATEX 2140 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; PF 08 CERT 1213 X — II 3G Ex nA nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 09.0019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTemperature measurement with local high\/low alarms\u003c\/li\u003e\n\u003cli\u003eOver-temperature trips on heaters, bearings and reactors\u003c\/li\u003e\n\u003cli\u003eRedundant thermocouple monitoring\u003c\/li\u003e\n\u003cli\u003eSIL 2 temperature limit functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting (40 mm wide) with 24 V DC from the Power Rail or terminals 23+\/24-. Sensor connects to terminals 1, 2, 3, 4, 6; relays on 10–12 and 16–18; analogue output on 8+\/7-.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-GUT-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-GUT-Ex1.D is a 1-channel isolated barrier temperature converter with trip values. It accepts thermocouple (including redundant TC), RTD, potentiometer or voltage inputs from the hazardous area and provides a 0\/4 … 20 mA analogue output plus two relay contact outputs for temperature alarms.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-GUT-Ex1.D need?\u003c\/h3\u003e\u003cp\u003e20 … 30 V DC (Power Rail or terminals 23+, 24-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-GUT-Ex1.D?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/231225_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-GUT-Ex1.D datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/48362\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-GUT-Ex1.D on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-ut2-ex1-temperature-converter\"\u003ePepperl+Fuchs KFD2-UT2-Ex1 – Universal Temperature Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-crg2-ex1-d-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-CRG2-Ex1.D – Transmitter Power Supply with Trip Values\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-GUT-Ex1.D. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161109393733,"sku":"KFD2-GUT-Ex1.D","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-gut-ex1-d-temperature-converter-with-trip-values.jpg?v=1794323954"},{"product_id":"pepperl-fuchs-kfd0-sd2-ex2-1045-solenoid-driver","title":"Pepperl+Fuchs KFD0-SD2-Ex2.1045 – Solenoid Driver","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD0-SD2-Ex2.1045 is a 2-channel isolated barrier solenoid driver. It is loop powered from the 24 V DC control signal and drives intrinsically safe solenoid valves, alarms and LEDs in the hazardous area, with each output current-limited to 45 mA at 10 V DC.\u003c\/p\u003e\n\u003cp\u003eBecause it is loop powered, no separate supply is required. The module is ATEX and IECEx certified for Ex ia outputs and is suitable for applications up to SIL 3 to IEC\/EN 61508, making it a common choice for on\/off valve actuation in safety and process control systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD0-SD2-Ex2.1045\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Solenoid Driver\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eLoop powered from 20 … 35 V DC control signal\u003c\/li\u003e\n\u003cli\u003eCurrent limit 45 mA at 10 V DC per channel\u003c\/li\u003e\n\u003cli\u003eDrives Ex i solenoid valves, alarms and LEDs\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003cli\u003eUp to SIL 3 to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD0-SD2-Ex2.1045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel solenoid driver \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSupply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC, loop powered (control side terminals 7, 8; 8, 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e72 mA at 20 V; 50 mA at 35 V (220 Ω load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eTerminals 1+, 2-; 4+, 5-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 45 mA at ≥ 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInternal resistance Ri\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 282 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOpen loop voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emin. 22.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e\u0026lt; 1.05 W per channel (≤ 30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 3 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 107 x 115 mm (W x H x D), housing type B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBASEEFA 06 ATEX 0252 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 06.0058, IECEx CML 19.0093X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntrinsically safe solenoid valves on actuated valves\u003c\/li\u003e\n\u003cli\u003eEx-area alarm sounders and indicator LEDs\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown (ESD) valve actuation\u003c\/li\u003e\n\u003cli\u003eSIL 3 final element loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting; the unit is loop powered from the control-side signal on terminals 7, 8 \/ 8, 9 — no Power Rail supply. Solenoids connect to 1+\/2- and 4+\/5-. Verify the solenoid's Ex i parameters and minimum operating current against the barrier output data.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD0-SD2-Ex2.1045?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD0-SD2-Ex2.1045 is a 2-channel isolated barrier solenoid driver. It is loop powered from the 24 V DC control signal and drives intrinsically safe solenoid valves, alarms and LEDs in the hazardous area, with each output current-limited to 45 mA at 10 V DC.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD0-SD2-Ex2.1045 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC, loop powered (control side terminals 7, 8; 8, 9).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD0-SD2-Ex2.1045?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/242032_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD0-SD2-Ex2.1045 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/53136\" target=\"_blank\" rel=\"noopener\"\u003eKFD0-SD2-Ex2.1045 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-vr4-ex1-26-voltage-repeater\"\u003ePepperl+Fuchs KFD2-VR4-Ex1.26 – Voltage Repeater\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-eb2-power-feed-module\"\u003ePepperl+Fuchs KFD2-EB2 – Power Feed Module\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD0-SD2-Ex2.1045. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161112047941,"sku":"KFD0-SD2-Ex2.1045","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd0-sd2-ex2-1045-solenoid-driver.jpg?v=1794323956"}],"url":"https:\/\/valvesuk.com\/collections\/atex-hazardous-area-products.oembed","provider":"Valves UK","version":"1.0","type":"link"}