{"product_id":"pepperl-fuchs-kfd2-sra-ex4-switch-amplifier","title":"Pepperl+Fuchs KFD2-SRA-Ex4 – 4-Channel Switch Amplifier","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-SRA-Ex4 is a 4-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts NAMUR sensors or dry contacts and provides four relay contact outputs in a single 20 mm wide K-System module.\u003c\/p\u003e\n\u003cp\u003ePepperl+Fuchs 2:1 technology lets two field devices share one pair of field wires, reducing field wiring by up to 50 %. The module is supplied at 24 V DC via the Power Rail or terminals, offers line fault detection and a reversible mode of operation, and its inputs are ATEX and IECEx certified for Ex ia applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-SRA-Ex4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 4-Channel Switch Amplifier\u003c\/li\u003e\n\u003cli\u003e4-channel isolated barrier in one 20 mm module\u003c\/li\u003e\n\u003cli\u003eInputs for NAMUR sensors or dry contacts\u003c\/li\u003e\n\u003cli\u003e2:1 technology — up to 50 % less field wiring\u003c\/li\u003e\n\u003cli\u003e4 relay contact outputs\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail or terminals\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eReversible mode of operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-SRA-Ex4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4-channel isolated barrier \/ switch amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e45 … 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower dissipation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eNAMUR to EN 60947-5-6 or dry contact (terminals 1–6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLine fault detection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBreakage I ≤ 0.15 mA, short circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e4 × relay (terminals 7–12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eContact loading\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e253 V AC \/ 2 A \/ cos φ \u0026gt; 0.7; 40 V DC \/ 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSwitching frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 Hz (non-AC operation), ≤ 3 Hz (AC operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 119 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eZELM 99 ATEX 0009 — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx TUN 04.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh channel-count digital input systems\u003c\/li\u003e\n\u003cli\u003eValve position feedback with two sensors per valve\u003c\/li\u003e\n\u003cli\u003eReducing field cabling in retrofit projects\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor interfacing to PLC\/DCS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail or terminals 14+\/15-. 2:1 operation is set by DIP switch; see the manual for the required field circuit arrangement. Relay outputs connect to terminals 7–12. Follow the certificate and manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-SRA-Ex4?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-SRA-Ex4 is a 4-channel isolated barrier switch amplifier for transferring digital signals from hazardous areas to the safe area. It accepts NAMUR sensors or dry contacts and provides four relay contact outputs in a single 20 mm wide K-System module.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-SRA-Ex4 need?\u003c\/h3\u003e\u003cp\u003e19 … 30 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-SRA-Ex4?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/190176_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-SRA-Ex4 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/35550\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-SRA-Ex4 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-sr2-ex2-w-isolated-barrier\"\u003ePepperl+Fuchs KFD2-SR2-Ex2.W – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kcd2-sr-ex2-isolated-barrier\"\u003ePepperl+Fuchs KCD2-SR-Ex2 – Isolated Barrier Switch Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-SRA-Ex4. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161092288837,"sku":"KFD2-SRA-Ex4","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-sra-ex4-4-channel-switch-amplifier.jpg?v=1794323932","url":"https:\/\/valvesuk.com\/products\/pepperl-fuchs-kfd2-sra-ex4-switch-amplifier","provider":"Valves UK","version":"1.0","type":"link"}