{"product_id":"pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply","title":"Pepperl+Fuchs KFD2-STC4-Ex2 – 2-Channel SMART Transmitter Power Supply","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003cp\u003eHART communication is passed bi-directionally, and terminals with test points support commissioning and maintenance. The unit is supplied at 24 V DC via the Power Rail, is ATEX and IECEx certified for [Ex ia] inputs and is suitable for applications up to SIL 2 to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFD2-STC4-Ex2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 2-Channel SMART Transmitter Power Supply\u003c\/li\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003eSupplies 2-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003e0\/4 … 20 mA output per channel\u003c\/li\u003e\n\u003cli\u003eHART signals transferred bi-directionally\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via Power Rail\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 1rem\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eKFD2-STC4-Ex2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eProduct type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e2-channel SMART transmitter power supply \/ isolated barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eSignal type\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eAnalogue input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eRated supply voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003emax. 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eInput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA from 2-wire transmitters (terminals 1+, 3-; 4+, 6-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAvailable voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≥ 16 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0\/4 … 20 mA per channel (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eLoad\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e0 … 550 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDeviation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e≤ 10 µA at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eFunctional safety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eSIL 2 (IEC\/EN 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e-20 … 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDegree of protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e20 x 124 x 115 mm (W x H x D), housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMass\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003e35 mm DIN mounting rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eATEX\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eBAS 99 ATEX 7025 X — II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; TÜV 99 ATEX 1499 X — II 3G Ex nA II T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eIECEx\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eIECEx BAS 04.0015X, IECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border:1px solid rgba(0,0,0,.12);text-align:left;width:38%;padding:.6rem .9rem;vertical-align:top\"\u003eOther approvals\u003c\/th\u003e\n\u003ctd style=\"border:1px solid rgba(0,0,0,.12);padding:.6rem .9rem;vertical-align:top\"\u003eUL (E106378)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are taken from Pepperl+Fuchs manufacturer data. Always confirm critical values — particularly hazardous-area and functional-safety data — against the current datasheet, certificates and instruction manual before installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo analogue transmitter loops per module\u003c\/li\u003e\n\u003cli\u003ePressure, level and temperature transmitters in Ex zones\u003c\/li\u003e\n\u003cli\u003eHART asset management access\u003c\/li\u003e\n\u003cli\u003eSIL 2 measurement loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\u003cp\u003eDIN rail mounting with 24 V DC from the Power Rail. Transmitters connect to terminals 1+\/3- (channel I) and 4+\/6- (channel II); outputs are on 7-\/8+ and 10-\/11+. Observe the certificate and safety manual for intrinsically safe loop design.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pepperl+Fuchs KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThe Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier SMART transmitter power supply. Each channel powers a 2-wire SMART transmitter in the hazardous area and repeats its 0\/4 … 20 mA signal to the safe area, giving two independent analogue loops in one 20 mm wide K-System module.\u003c\/p\u003e\n\u003ch3\u003eWhat supply does the KFD2-STC4-Ex2 need?\u003c\/h3\u003e\u003cp\u003e20 … 35 V DC (Power Rail or terminals 14+, 15-).\u003c\/p\u003e\n\u003ch3\u003eHow do I get a price for the KFD2-STC4-Ex2?\u003c\/h3\u003e\u003cp\u003eThis product is sold on a price on availability basis. Use the \u003ca href=\"#poa-enquiry\"\u003eenquiry form\u003c\/a\u003e on this page with your quantity and application details and the Valves UK team will reply with pricing and lead time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Documentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/283699_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePepperl+Fuchs KFD2-STC4-Ex2 datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pepperl-fuchs.com\/en\/products-gp25581\/75015\" target=\"_blank\" rel=\"noopener\"\u003eKFD2-STC4-Ex2 on the Pepperl+Fuchs website\u003c\/a\u003e (certificates, manuals and drawings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc4-ex1-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pepperl-fuchs-kfd2-stc5-ex2-smart-transmitter-power-supply\"\u003ePepperl+Fuchs KFD2-STC5-Ex2 – 2-Channel SMART Transmitter Power Supply\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pepperl-fuchs\"\u003eView the full Pepperl+Fuchs range at Valves UK\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePrice and Availability\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePrice on Availability (POA)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eContact Valves UK for pricing, product availability and technical enquiries regarding the Pepperl+Fuchs KFD2-STC4-Ex2. Please include your required quantity and any relevant application details when submitting your enquiry.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":60161076232517,"sku":"KFD2-STC4-Ex2","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0956\/5542\/8421\/files\/pepperl-fuchs-kfd2-stc4-ex2-2-channel-smart-transmitter-power-supply.jpg?v=1794323901","url":"https:\/\/valvesuk.com\/products\/pepperl-fuchs-kfd2-stc4-ex2-smart-transmitter-power-supply","provider":"Valves UK","version":"1.0","type":"link"}